Problem Report 0057 Details

Help Show help | Quick Search | Click here to view your privileges

This page provides all information on Problem Report 0057.


Report 0057 Actions


    Problem Report Number 0057
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.PX.0028
    Raised 2010-12-10 09:53
    Updated 2010-12-13 10:37
    Published 2010-12-13 10:37
    Product Standard PSE52 Realtime Controller 1003.1-2003 System
    Certification Program POSIX Certified by IEEE and The Open Group
    Test Suite VSRT-PSE version 5.4.3
    Test Identification rt.os/timers/nanosleep/T.nanosleep 3 Failed
    Specification PSE52 Realtime Controller 1003.1-2003 System Product Standard
    Location in Spec 7.2.1 http://www.opengroup.org/onlinepubs/9699919799/functions/nanosleep.html
    Problem Summary T.nanosleep 3 is being "Failed" because of using floating-point with (double) type casting
    Problem Text <T.nanosleep 3> test should not use floating-point
    Test Output /tset/rt.os/timers/nanosleep/T.nanosleep 3 Failed

    Test Information:
    nanosleep() did not suspend the thread for the requested duration. requested time: 5.001000
    secs actual 5.001000

    Review Information

    Review Type TSMA Review
    Start Date 2010-12-10 09:53
    Last Updated 2010-12-13 10:13
    Completed 2010-12-13 10:13
    Status Complete
    Review Recommendation Test Suite Deficiency (TSD)
    Review Response This is accepted as a fault in the test suite.

    Review Type SA Review
    Start Date 2010-12-13 18:13
    Last Updated 2010-12-13 10:36
    Completed 2010-12-13 10:36
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion A test suite deficiency is granted.

    Problem Reporting System Options:

     

    Back   