Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2749 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2749.
Report 2749 Actions
Problem Report Number 2749 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0132 Raised 2023-07-18 09:34 Updated 2023-07-18 09:38 Published 2023-07-18 09:38 Expiry Date 2024-07-18 Product Standard Commands and Utilities V4 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSC version 5.3.22NW Test Identification /tset/POSIX.annexA/c99/c99.ex{30}, /tset/POSIX.annexA/c99/c99.ex{123} Specification Shell and Utilities Issue 6 Location in Spec https://pubs.opengroup.org/onlinepubs/009695399/utilities/c99.html Problem Summary c99 with -o on an unwritable file should return an error Problem Text When c99 is called on an unwritable file it should return an error message and have a non-zero
exit-value. However, in the the current implementation it fails to meet this requirement and cause
these two tests to fail identically:
/tset/POSIX.annexA/c99/c99.ex{30}
/tset/POSIX.annexA/c99/c99.ex{123}Test Output /tset/POSIX.annexA/c99/c99.ex Assertion: 30
400|186 30 1 04:41:01|IC Start
520|186 30 19443 1 1|Assertion #30 (C):
520|186 30 19443 2 1|Expected exit code != 0; Received 0
520|186 30 19443 2 2|Standard error is empty
220|186 30 1 04:41:01|FAIL
410|186 30 1 04:41:01|IC End
/tset/POSIX.annexA/c99/c99.ex Assertion: 123
400|186 123 1 04:42:00|IC Start
520|186 123 19443 1 1|Assertion #123 (C):
520|186 123 19443 2 1|Testing: -I with inaccessible directory...
520|186 123 19443 2 2|Testing: -L with inaccessible directory...
520|186 123 19443 2 3|Testing: -o with unwritable output file...
520|186 123 19443 2 4|Expected exit code != 0; Received 0
520|186 123 19443 2 5|Standard error is empty
220|186 123 1 04:42:00|FAIL
410|186 123 1 04:42:00|IC EndReview Information
Review Type SA Review Start Date 2023-07-18 09:34 Last Updated 2023-07-18 09:38 Completed 2023-07-18 09:38 Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion A minor system fault is granted.