Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2744 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2744.
Report 2744 Actions
Problem Report Number 2744 Submitter's Classification Test Suite problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0298 Raised 2022-12-23 12:03 Updated 2022-12-23 12:03 Published 2022-12-23 12:03 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 5.3.22 Test Identification /tset/POSIX.cmd/dd/dd.ex 46 Specification Commands and Utilities Issue 4 Version 2 Location in Spec SUSv1, page 62 Problem Summary When a SIGINT signal is received, then dd writes status information to the
standard error and exits. For UNIX 95 and UNIX 98 modes, the exit status
is non-zero.Problem Text Refer to Request #1302.
SUSv1, page 62:
"When a command is in an asynchronous list, the shell will prevent SIGQUIT
and SIGINT signals from the keyboard from interrupting the command."
It allows the "trap - INT" to have no effect. A PIN is granted to cover this
test failure.
Thanks!Test Output 400|29 46 1 08:42:09|IC Start
200|29 44 08:42:09|TP Start
520|29 44 50397511 1 1|Assertion #46 (A): Check when SIGINT received, dd
writes status to error stream.
520|29 44 50397511 2 1|Command failed: '[ "0" -gt 0 ]'
220|29 44 1 08:42:19|FAIL
410|29 46 1 08:42:19|IC EndReview Information
Review Type TSMA Review Start Date 2022-12-23 12:03 Last Updated 2022-12-23 09:15 Completed 2022-12-23 09:15 Status Complete Review Recommendation Permanent Interpretation (PIN) Review Response This test relies on "trap - INT" in a background subshell resetting the
disposition of SIGINT to default (so that it will be inherited as default
by dd). In SUSv4 a clarification has been made requiring this behavior,
but in SUSv1 through SUSv3 the wording (quoted by the submitter) could be
interpreted as allowing the trap to have no effect.
It is not possible to alter the test to use a different strategy,
therefore it is recommended that a PIN is granted.
Review Type SA Review Start Date 2022-12-23 17:15 Last Updated 2022-12-23 12:03 Completed 2022-12-23 12:03 Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion A permanent interpretation is granted.
Problem Reporting System Options:
- View Report 2744
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority