Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2734 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2734.
Report 2734 Actions
Problem Report Number 2734 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0127 Raised 2021-08-12 04:20 Updated 2021-09-13 10:01 Published 2021-09-13 10:01 Expiry Date 2022-09-13 Product Standard C Language V2 (UNIX 03) Certification Program The Open Brand certification program Test Suite Perennial Test Identification P74932.c Specification ISO/IEC 9899:1999 Location in Spec §7.23.1 Problem Summary sizeof(CLOCKS_PER_SEC) is not the same as sizeof(clock_t) Problem Text The standard states (?7.23.1) that the symbol CLOCKS_PER_SEC defined in <time.h> "expands to
a constant expression with type clock_t". In our implementation CLOCKS_PER_SEC is implicitly
defined as an int, which is 4 bytes long, whereas an object of type clock_t is 8 bytes long.Test Output ===P74932.c
ISO/IEC 9899:1999, 7.23.1 Components of time
Enter Block #0
Exit Block #0 passed
Enter Block #1
Exit Block #1 passed
Enter Block #2
Exit Block #2 passed
Enter Block #3
CLOCKS_PER_SEC is not the same size as clock_t.
Exit Block #3 FAILReview Information
Review Type SA Review Start Date 2021-08-12 04:20 Last Updated 2021-09-13 10:00 Completed 2021-09-13 10:00 Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion A minor system fault is granted.