Report 2734 Actions


    Problem Report Number 2734
    Submitter's Classification Minor System Fault
    State Resolved
    Resolution Minor System Fault (MSF)
    Problem Resolution ID MSF.X.0127
    Raised 2021-08-12 04:20
    Updated 2021-09-13 10:01
    Published 2021-09-13 10:01
    Expiry Date 2022-09-13
    Product Standard C Language V2 (UNIX 03)
    Certification Program The Open Brand certification program
    Test Suite Perennial
    Test Identification P74932.c
    Specification ISO/IEC 9899:1999
    Location in Spec §7.23.1
    Problem Summary sizeof(CLOCKS_PER_SEC) is not the same as sizeof(clock_t)
    Problem Text The standard states (?7.23.1) that the symbol CLOCKS_PER_SEC defined in <time.h> "expands to
    a constant expression with type clock_t". In our implementation CLOCKS_PER_SEC is implicitly
    defined as an int, which is 4 bytes long, whereas an object of type clock_t is 8 bytes long.
    Test Output ===P74932.c
    ISO/IEC 9899:1999, 7.23.1 Components of time
    Enter Block #0
    Exit Block #0 passed

    Enter Block #1
    Exit Block #1 passed

    Enter Block #2
    Exit Block #2 passed

    Enter Block #3
    CLOCKS_PER_SEC is not the same size as clock_t.
    Exit Block #3 FAIL

    Review Information

    Review Type SA Review
    Start Date 2021-08-12 04:20
    Last Updated 2021-09-13 10:00
    Completed 2021-09-13 10:00
    Status Complete
    Review Resolution Minor System Fault (MSF)
    Review Conclusion A minor system fault is granted.