Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2689 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2689.
Report 2689 Actions
Problem Report Number 2689 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.1407 Raised 2017-08-07 22:07 Updated 2017-08-07 17:06 Published 2017-08-07 17:06 Product Standard Internationalised System Calls and Libraries Extended V3 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSRT version 5.4.13 Test Identification /tset/rt.os/aio/aio_error/T.aio_error{3} Specification Base Definitions Issue 6 Problem Summary Test should write "x\n" instead of "xx" if the asynchronous I/O
operation has not yet completed.Problem Text Test doesn't write "x\n" instead of "xx" if the asynchronous I/O
operation is not completed, and timed-out error is coming.
Test Output 10|0 /tset/rt.os/aio/aio_error/T.aio_error 02:02:56|TC Start, scenario
ref 1-0, ICs: {3}
15|0 3.6-lite 1|TCM Start
400|0 3 1 02:02:56|IC Start
200|0 3 02:02:56|TP Start
520|0 3 00012189904 1 1|> test with pipe
520|0 3 00012189904 2 1|> test with pty
520|0 3 00012189904 3 1|vsrt_wait_for: Timed-out waiting for child to exit
520|0 3 00012189904 3 2|> test with tty
520|0 3 00012189904 3 3|tty testing not configured
520|0 3 00012189904 3 4|> test with pipe
520|0 3 00012189904 4 1|> test with pty
520|0 3 00012189904 5 1|> test with tty
520|0 3 00012189904 5 2|tty testing not configured
220|0 3 1 02:05:10|FAIL
410|0 3 1 02:05:10|IC End
80|0 0 02:05:13|TC End, scenario ref 1-0
900|02:05:13|TCC EndReview Information
Review Type TSMA Review Start Date 2017-08-07 22:07 Last Updated 2017-08-07 16:34 Completed 2017-08-07 16:34 Status Complete Review Recommendation Test Suite Deficiency (TSD) Review Response This is accepted as a fault in the test suite.
Review Type SA Review Start Date 2017-08-08 00:34 Last Updated 2017-08-07 17:06 Completed 2017-08-07 17:06 Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion A test suite deficiency is granted.
Problem Reporting System Options:
- View Report 2689
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority