Report 2681 Actions
Problem Report Number 2681 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0115 Raised 2016-08-17 10:05 Updated 2016-08-17 10:31 Published 2016-08-17 10:31 Expiry Date 2017-08-17 Product Standard Commands and Utilities V4 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSC version 5.3.10 Test Identification POSIX.cmd/awk/awk.ex 31, 48 Specification Shell and Utilities Issue 6 Location in Spec Assertion 21 in section 4.1.3 of standard P1003.3.2/D8. Problem Summary Assignment to a variable, using either the -v option or an assignment
operand, fails when the assigned value is '=' (an equal sign)Problem Text When awk is invoked with the options '-v var==' or '-v var="="' then var
is not assigned the value
of an = sign character. In an awk operand, the assignment
var==
does not assign to var the value of an = sign character.Test Output Assertion #31 (A): awk performs -v assignments before program
execution
Expected exit code = 0; Received 2
"^=$" wasn't found in standard output
Standard error isn't empty
Contents of out.stderr:
awk: invalid -v option
Assertion #48 (A): An arg with syntax <ident>=... is treated as an
assignment
Expected exit code = 0; Received 2
"^=$" wasn't found in standard output
Standard error isn't empty
Contents of out.stderr:
awk: can't open file var==
input record number 4, file var==
source line number 1Review Information
Review Type SA Review Start Date 2016-08-17 10:05 Last Updated 2016-08-17 10:31 Completed 2016-08-17 10:31 Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion A minor system fault is granted.