Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2675 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2675.
Report 2675 Actions
Problem Report Number 2675 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.1398 Raised 2016-08-10 10:59 Updated 2016-08-10 10:15 Published 2016-08-10 10:15 Product Standard Internationalised System Calls and Libraries Extended V3 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSTH version 5.5.10 Test Identification tset/PTHR.os/sched_rt/pthread_setschedprio/T.pthread_setschedprio 1
Specification Base Definitions Issue 6 Problem Summary When the maximum and minimum priorities for SCHED_OTHER are the same,
the test tries to use minimum+1 which fails.Problem Text On our implementation, the maximum and minimum priorities for
SCHED_OTHER are the same. The test tries to use minimum+1 which fails.Test Output /tset/PTHR.os/sched_rt/pthread_setschedprio/T.pthread_setschedprio 1
Unresolved
Test Description:
If the _POSIX_THREAD_PRIORITY_SCHEDULING option is supported:
A call to pthread_setschedprio(key, value) shall set the scheduling
priority
for the thread whose thread ID is given by thread to the value by
prio,
and
return 0.
Test Information:
pthread_attr_setschedparam, expected 0, got 22Review Information
Review Type TSMA Review Start Date 2016-08-10 10:59 Last Updated 2016-08-10 10:11 Completed 2016-08-10 10:11 Status Complete Review Recommendation Test Suite Deficiency (TSD) Review Response This is accepted as a fault in the test suite.
Review Type SA Review Start Date 2016-08-10 18:11 Last Updated 2016-08-10 10:15 Completed 2016-08-10 10:15 Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion A test suite deficiency is granted