Problem Report Number 2601 Submitter's Classification Test Suite problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0289 Raised 2015-03-10 23:15 Updated 2015-03-11 11:17 Published 2015-03-11 11:17 Product Standard Commands and Utilities V4 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSC version 5.3.8NW Test Identification /tset/POSIX.upe/man/man.ex:18 Specification Shell and Utilities Issue 6 Location in Spec page 632, line 24571
STDERR
The standard error shall be used only for diagnostic messages.Problem Summary /tset/POSIX.upe/man/man.ex:18 FAILs in SUSv3 and it should not. Problem Text Solaris man writes out the diagnostic message if there is no preformated
man page after clean install. The command succeeds. Standard doesn't
seem to disallow that.
It was allowed to informational messages to be written to stderr in
SUSv4. SUSv3 required that it only be used for diagnostic messages.
We would like to keep the number of steps making the Solaris system Unix
conforming minimal so I am kindly asking for PIN on this case.Test Output Assertion #18 (C): GA40: no standard error is written on success
Standard error isn't empty
Contents of out.stderr:
Reformatting page. Please Wait... doneReview Information
Review Type TSMA Review Start Date 2015-03-10 23:15 Last Updated 2015-03-10 16:31 Completed 2015-03-10 16:31 Status Complete Review Recommendation Permanent Interpretation (PIN) Review Response This was submitted as a TSD but it is clear from the problem text that
the submitter is actually requesting a PIN.
The SUSv3 requirement does not match existing practice and this has been
corrected in SUSv4. Therefore a PIN is recommended.