Problem Report Number 2586 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0288 Raised 2013-01-17 09:46 Updated 2013-01-18 19:18 Published 2013-01-18 19:18 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 535 Test Identification /tset/POSIX.cmd/mailx/mailx_02.ex 129 Specification Commands and Utilities Issue 4 Version 2 Location in Spec see problem text Problem Summary The "next" command of mailx does not read current message Problem Text This unit fails after we update VSC5 to version 5.3.5, the reason is
when our "mailx" starts, it automatically opens first message, when it
reads "next" command, it will output the second message. In this unit,
our "mailx" outputs "THIS IS IN MESSAGE 2", not "THIS IS IN MESSAGE 1".
The description of "next" command of "mailx" in POSIX.2-1992 is too
simple. And the description in POSIX.2b is much clear. Because currently
we are trying to get certification for UNIX95. So we want to get a PIN
for this unit.
Thanks!Test Output 400|67 129 1 22:31:29|IC Start
200|67 50 22:31:29|TP Start
520|67 50 83952985 1 1|Assertion #129 (C): With no message argument, the
default is the current message
520|67 50 83952985 4 1|"IN MESSAGE 1" wasn't found in standard output
220|67 50 1 22:31:29|FAIL
410|67 129 1 22:31:29|IC EndReview Information
Review Type SA Review Start Date 2013-01-17 09:46 Last Updated 2013-01-18 19:17 Completed 2013-01-18 19:17 Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion The description of the mailx "next" command in SUSv1 was as follows:
Synopsis: n[ext] [message]
Go to the next message that matches message.
In SUSv3 and SUSv4 this has been replaced with a much more thorough
description (from the POSIX.2b amendment).
A permanent interpretation is granted. It should be noted that
systems needing to reference this PIN when
certifying doe not match widespread existing practice and will need to
change if they wish to conform to SUSv3 or SUSv4.