Problem Report Number 2568 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.1332 Raised 2011-08-09 21:17 Updated 2011-08-15 10:37 Published 2011-08-15 10:37 Product Standard Internationalised System Calls and Libraries Extended V3 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSU version 5.3.3 Test Identification CAPI.os/sysdb/endgrent/T.endgrent.1
CAPI.os/sysdb/endpwent/T.endpwent.1Specification Base Definitions Issue 6 Problem Summary Sporadic failures of CAPI.os/sysdb/endgrent/T.endgrent.1 and T.endpwent.1 Problem Text Failure is reported when the value of the first available file
descriptor changes during a test run. The inherent assumption that any
file descriptor activity must be indicative of a failure to have closed
the user/group database does not appear to be warranted; testing
indicates that the file descriptor in the failure instances is not
related to the user/group database file.Test Output /tset/CAPI.os/sysdb/endgrent/T.endgrent 1 Failed
Test Description:
Base Required Conformance
A call to void endgrent(void) shall close the group database opened by
a prior call to getgrent().
Test Information:
PREP: Obtain first available file descriptor
PREP: Issue getgrent
PREP: Obtain next available file descriptor
PREP: Find file descriptor used by getgrent
TEST: endgrent closes group database
ERROR: endgrent failed to group database
/tset/CAPI.os/sysdb/endpwent/T.endpwent 1 Failed
Test Description:
Base Required Conformance
A call to void endpwent(void) shall close the user database opened by
a prior call to getpwent().
Test Information:
PREP: Obtain first available file descriptor
PREP: Issue getpwent
PREP: Obtain next available file descriptor
PREP: Find file descriptor used by getpwent
TEST: endpwent closes password database
ERROR: endpwent failed to close databaseReview Information
Review Type TSMA Review Start Date 2011-08-09 21:17 Last Updated 2011-08-15 10:01 Completed 2011-08-15 10:01 Status Complete Review Recommendation Test Suite Deficiency (TSD) Review Response This is accepted as a fault in the test suite.
Review Type SA Review Start Date 2011-08-15 18:01 Last Updated 2011-08-15 10:36 Completed 2011-08-15 10:36 Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion A test suite deficiency is granted.