Problem Report 2495 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2495.
Report 2495 Actions
Problem Report Number 2495 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0101 Raised 2006-01-07 05:07 Updated 2006-01-11 19:41 Published 2006-01-11 19:41 Expiry Date 2006-01-11 Product Standard Internationalised System Calls and Libraries Extended V3 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSX4 version 4.6.4 Test Identification /tset/POSIX.os/devclass/c_oflag_X/T.c_oflag_X 2 Specification Base Definitions Issue 6 Location in Spec As per understanding of the problem. Problem Summary Although the autopush modules are correct, the below failure for
c_oflag_X{2} happens. Looks like ONLCR transformation is done twice.Problem Text This failure happens as the ONLCR transformation is done twice, one by
the autopush modules itself and the other by the device driver for the
serial port. A Minor System Fault is requested for this failureTest Output /tset/POSIX.os/devclass/c_oflag_X/T.c_oflag_X 2 Failed
Test Description:
When ONLCR is set, the NL character is translated into the CR-NL
sequence on output.
Test Strategy:
OPEN and initialise terminal file and loop back file
SET OPOST and ONLCR in terminal control flags
FOR buffers of 128 characters:
CREATE process pair
CHILD process:
WRITE data to terminal file (comprising all character values
up to
the maximum supported character size)
PARENT process:
READ from loop back file
VERIFY that read() returned size of data written plus 1
VERIFY that the NL character is translated into the sequence
CR-NL
and all other characters are unchanged
Test Information:
read() returned 130, expected 129
NL character was not transmitted as CR-NL, received 015-015Review Information
Review Type SA Review Start Date 2006-01-07 05:07 Last Updated 2006-01-11 02:08 Completed 2006-01-11 02:08 Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion The SA agrees that the issue raised in this PR is consistent with a
Minor System Fault
Problem Reporting System Options:
- View Report 2495
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority