    Problem Report Number 2485
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.1289
    Raised 2005-10-27 17:18
    Updated 2005-10-28 17:57
    Published 2005-10-28 17:57
    Product Standard LDAP Certified
    Certification Program The Open Brand certification program
    Test Suite VSLDAP version 2.2GA
    Test Identification parsing3_3_0_18
    conversion3_2_4_1
    Specification IETF RFC2253
    Problem Summary In tests relevant to BER encoding with right type
    Problem Text In RFC 2253, it states that:
    If the AttributeValue is of a type which does not have a string
    representation defined for it, then it is simply encoded as an
    octothorpe character ('#' ASCII 35) followed by the hexadecimal
    representation of each of the bytes of the BER encoding of the
    X.500 AttributeValue.

    In the tests parsing3_3_0_18 and conversion3_2_4_1, searches with the
    base object 2.5.4.3=#04027569,ou=Corporate
    Tax,ou=Fin-Accounting,ou=Americas,ou=Search,o=IMC,c=US are using a
    attribute value which of a type that does has a string representation.

    Review Information

    Review Type TSMA Review
    Start Date 2005-10-27 17:18
    Last Updated 2005-10-27 18:24
    Completed 2005-10-27 18:24
    Status Complete
    Review Recommendation Test Suite Deficiency (TSD)
    Review Response As the test assumption is wrong, it is accepted a defect in the test suite.

    Review Type SA Review
    Start Date 2005-10-27 17:24
    Last Updated 2005-10-28 02:48
    Completed 2005-10-28 02:48
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion This PR is approved as a Test Suite Deficiency