    Problem Report Number 2409
    Submitter's Classification Specification problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.1247
    Raised 2004-07-23 03:36
    Updated 2004-07-27 14:08
    Published 2004-07-27 14:08
    Product Standard Commands and Utilities V4 (UNIX 03)
    Certification Program The Open Brand certification program
    Test Suite VSC version 5.2.4A
    Test Identification POSIX.annexA/c99/c99.ex 16
    Specification Shell and Utilities Issue 6
    Location in Spec Page: 214 Line: 8400 Section: c99_OUTPUT_FILES
    Problem Summary Testcase fails when output file is an existing FIFO, test expects output
    to be written to the FIFO. An interpretation request has been approved
    that changes the expected behaviour.
    Problem Text Interpretation request 20 has approved a change in the SUSv3 C99 command
    to be referred back to the sponsors. This interpretation allows the C99
    command to issue a diagnostic message and non-zero exit status if the
    output file is of type FIFO.

    Until the sponsors can take action, we request that a TIN be issued for
    this VSC c99 test failure.
    Test Output ***********************************************************************
    /tset/POSIX.annexA/c99/c99.ex 16 Failed


    Test Information:
    Assertion #16 (C):
    c99 gave non-zero exit status when a.out is a FIFO
    c99 gave non-zero exit status when c99_16_exe is a FIFO
    c99 did not write any data to simple1.o when it was a FIFO

    ***********************************************************************

    Review Information

    Review Type SA Review
    Start Date 2004-07-23 03:36
    Last Updated 2004-07-24 00:37
    Completed 2004-07-24 00:37
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion This PR represents an agreed Test Suite Deficiency