HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 2346 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 2346.


Report 2346 Actions


    Problem Report Number 2346
    Submitter's Classification Specification problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0259
    Raised 2004-03-17 00:13
    Updated 2004-03-19 23:56
    Published 2004-03-19 23:56
    Product Standard Commands and Utilities V2 (UNIX 95)
    Certification Program The Open Brand certification program
    Test Suite VSC version 5.2.4
    Test Identification /POSIX.upe/vi/vi_04 247
    Specification Commands and Utilities Issue 4 Version 2
    Location in Spec vi
    Problem Summary PIN to allow old expected behavior for vi regarding the cursor position
    after then second "p" for VSC5.2.4 which was updated to align with
    POSIX.1-2001
    Problem Text VSC5.2.4 POSIX.upe/vi test 247 has been aligned with POSIX.1-2001 as
    regards the cursor position after the second "p". As this is also the
    historical behaviour, the test expects the same result in all test
    modes (not just POSIX01 and UNIX03). The old expected behaviour is
    still allowed for UNIX95 and UNIX98 compliance, the modified tests
    have just switched from expecting one of the allowed behaviours to
    the other one.

    We are applying for a PIN for UNIX95 mode.
    Test Output 400|33 247 1 20:36:11|IC Start
    200|33 49 20:36:11|TP Start
    520|33 49 67240123 1 1|Assertion #247 (C): p command on parts of lines
    520|33 49 67240123 6 1|Standard output isn't the same as file 'vi_exp_1'
    520|33 49 67240123 6 2|diff of "out.stdout" and "vi_exp_1":
    520|33 49 67240123 6 3|*** out.stdout Thu Feb 26 20:36:50 2004
    520|33 49 67240123 6 4|--- vi_exp_1 Thu Feb 26 20:36:11 2004
    520|33 49 67240123 6 5|***************
    520|33 49 67240123 6 6|*** 1,5 ****
    520|33 49 67240123 6 7| fcon1irst
    520|33 49 67240123 6 8| second line
    520|33 49 67240123 6 9| third or penult line
    520|33 49 67240123 6 10|! lline
    520|33 49 67240123 6 11|! third or 2ast one
    520|33 49 67240123 6 12|--- 1,5 ----
    520|33 49 67240123 6 13| fcon1irst
    520|33 49 67240123 6 14| second line
    520|33 49 67240123 6 15| third or penult line
    520|33 49 67240123 6 16|! ll2ine
    520|33 49 67240123 6 17|! third or ast one
    220|33 49 1 20:36:50|FAIL
    410|33 247 1 20:36:50|IC End

    Review Information

    Review Type SA Review
    Start Date 2004-03-17 00:13
    Last Updated 2004-03-17 01:01
    Completed 2004-03-17 01:01
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion A permanent interpretation is granted to permit POSIX.1-2001
    historical behaviour


    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority