Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 2311 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 2311.
Report 2311 Actions
Problem Report Number 2311 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.1187 Raised 2004-01-23 01:21 Updated 2004-01-27 18:19 Published 2004-01-27 18:19 Product Standard Internationalised System Calls and Libraries Extended V3 (UNIX 03) Certification Program The Open Brand certification program Test Suite VSX4 Test Identification POSIX.os/procenv/sysconf_X/T.sysconf_X.12 Specification Unknown Location in Spec Both the sysconf and unistd.h pages Problem Summary /tset/POSIX.os/procenv/sysconf_X/T.sysconf_X 12 FAIL
sysconf(_SC_2_C_VERSION) failed expected 200112 - got 199209Problem Text The failing assertion:
/tset/POSIX.os/procenv/sysconf_X/T.sysconf_X 12 FAIL
sysconf(_SC_2_C_VERSION) failed expected 200112 - got 199209
Since _SC_2_C_VERSION has been removed from TC2,
perhaps the test should stop testing for it.Test Output /tset/POSIX.os/procenv/sysconf_X/T.sysconf_X 12 FAIL
sysconf(_SC_2_C_VERSION) failed expected 200112 - got 199209Review Information
Review Type TSMA Review Start Date 2004-01-23 01:21 Last Updated 2004-01-23 17:44 Completed 2004-01-23 17:44 Status Complete Review Recommendation No Resolution Given Review Response Unfortunately this request has been made for the wrong product standard.
It relates to UNIX03 but has been requested for XPG4.
If the database record can be corrected to show the correct product
standard then a TSD should be issued. Otherwise the request should be
rejected.
Review Type SA Review Start Date 2004-01-23 17:44 Last Updated 2004-01-27 18:19 Completed 2004-01-27 18:19 Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion A test suite deficiency is granted (please note that we corrected the
product standard that this item was filed against).