Problem Report Number 2277 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0257 Raised 2003-08-20 13:43 Updated 2003-08-24 16:09 Published 2003-08-24 16:09 Product Standard Internationalised System Calls and Libraries Extended V2 (UNIX 98) Certification Program The Open Brand certification program Test Suite VSX4 version 4.5.4 Test Identification ANSI.os/streamio/printf Specification System Interfaces and Headers Issue 5 Location in Spec See Problem Text Linked Problem Reports PIN.X.0226 Problem Summary This is a known grey area in XSH5 for which there is a
working group resolution, bwg98-006. The test output has changed.Problem Text This is a known grey area in XSH5 for which there is a working
group resolution, bwg98-006. The two tests in VSX4:
ANSI.os/streamio/snprintf 68
and
ANSI.os/streamio/vsnprintf 68
expect the "new" behaviour identified in the resolution, and report
the failures shown above on systems which implement snprintf() and
vsnprintf() as per the original XSH5 specification.
A Permanent Interpretation is requested to cover these failures.Test Output 10|4 /tset/ANSI.os/streamio/printf/T.snprintf 08:53:58|TC Start,
scenario ref 5-
0
...
400|4 59 1 08:54:00|IC Start
200|4 59 08:54:00|TP Start
520|4 59 00007053 1 1|snprintf(buf, 0, "x") returned 1, expected < 1
220|4 59 1 08:54:00|FAIL
410|4 59 1 08:54:00|IC End
...
10|6 /tset/ANSI.os/streamio/vprintf/T.vsnprintf 08:54:02|TC Start,
scenario ref
7-0
...
400|6 59 1 08:54:04|IC Start
200|6 59 08:54:04|TP Start
520|6 59 00007237 1 1|vsnprintf(buf, 0, ...) returned 1, expected < 1
220|6 59 1 08:54:04|FAIL
410|6 59 1 08:54:04|IC EndReview Information
Review Type SA Review Start Date 2003-08-20 13:43 Last Updated 2003-08-24 02:40 Completed 2003-08-24 02:40 Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion As stated by the submitter, this is the same issue as PIN.X.0226 but
the test changed slightly when the UNIX03 changes were done and the
output differs from that shown in PIN.X.0226. A permanent
interpretation PIN is granted for convenience in analyzing test output.