Problem Report 2241 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 2241.


Report 2241 Actions


    Problem Report Number 2241
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.1150
    Raised 2003-04-07 17:35
    Updated 2003-04-07 18:44
    Published 2003-04-07 18:44
    Product Standard Window System Application Interface V2
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.1.3
    Test Identification Xt9/XtAppAddWorkProc 3
    Problem Summary TSD4W.00177 A timing problem may cause this test to report an
    intermittent XIOError.
    Problem Text Here pls find the analysis from an engineer of Xserver group:

    ------------
    Xserver will restart itself once the last client exit. The restart
    process takes some time because Xserver needs to release and realloc
    all the resources. During the period of time that Xserver restart any
    attampt to generate a connection to Xserver may fail because Xserver
    is just not ready. This is the reason why XOpenDisplay() sometimes
    fails. In the case of XtAppAddWorkProc, there are 5 test purposes:
    t001 to t005. Only one purpose runs at one time, that is the only X
    client, once it finished, Xserver restarts. So Xserver should restart
    5 times during XtAppAddWorkProc test.

    There is a period of time between the test case exit and Xserver
    re-start which makes the test case sometimes PASS and sometimes FAIL.

    -------------

    Could we extend the time-slot between the test cases, in terms of exit
    as VSW design?
    Test Output 520|2482 3 00019496 1 1|VSW5TESTSUITE PURPOSE 3
    520|2482 3 00019496 1 2|Assertion XtAppAddWorkProc-3.(A)
    520|2482 3 00019496 1 3|When a work procedure registered by a call to
    XtWorkProcId
    520|2482 3 00019496 1 4|XtAppAddWorkProc(app_context, proc, client_data)
    returns
    520|2482 3 00019496 1 5|True it shall be unregistered and not called
    when the
    520|2482 3 00019496 1 6|specified application context next waits for
    event input.
    520|2482 3 00019502 1 1|PREP: Initialize toolkit, Open display and
    Create topLevel root widget
    520|2482 3 00019502 1 2|ERROR:
    ****************************************************
    520|2482 3 00019502 1 3|ERROR: An unexpected XIOError occurred while testing
    520|2482 3 00019502 1 4|ERROR: Check for server disconnect
    520|2482 3 00019502 1 5|ERROR:
    ****************************************************
    520|2482 3 00019501 2 1|ERROR: Expected XtWKP_Proc invoked count of 5,
    Received 0
    220|2482 3 1 00:56:58|FAIL

    Review Information

    Review Type TSMA Review
    Start Date 2003-04-07 17:35
    Last Updated 2003-04-07 18:37
    Completed 2003-04-07 18:37
    Status Complete
    Review Recommendation Test Suite Deficiency (TSD)
    Review Response After discussions with the submitter, this failure has been found
    to be caused by a fault in the test suite. (Although the nature
    of the fault is different from the one claimed.)

    A TSD is recommended.

    Review Type SA Review
    Start Date 2003-04-07 17:37
    Last Updated 2003-04-07 18:42
    Completed 2003-04-07 18:42
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion This is an agreed Test Suite Deficiency.