HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 2158 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 2158.


Report 2158 Actions


    Problem Report Number 2158
    Submitter's Classification Specification problem
    State Resolved
    Resolution Temporary Interpretation (TIN)
    Problem Resolution ID TIN.X.0098
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1998-03-05 08:00
    Product Standard Motif Toolkit
    Certification Program The Open Brand certification program
    Test Suite VSM version 4.0.0
    Test Identification headers/Xm/DragDrop.h 9
    Specification Motif Toolkit API
    Location in Spec See Problem Text
    Problem Summary TIN4M.00005 I do not believe that XmDropSiteRegistered() is a Motif 1.2 function. The OSF/Motif Programmer's Reference (Rel 1.2) does not have that function.
    Problem Text

    I do not believe that XmDropSiteRegistered() is a Motif 1.2 function. The
    OSF/Motif Programmer's Reference (Rel 1.2) does not have that function.

    Test Output
    REQUEST/PROBLEM DESCRIPTION:

    520|100 9 15371 1 1|VSM4TESTSUITE PURPOSE 9
    520|100 9 15371 1 2|The function Boolean XmDropSiteRegistered(Widget)
    520|100 9 15371 1 3|shall be defined with the correct prototype in
    520|100 9 15371 1 4|Xm/DragDrop.h.
    520|100 9 15371 1 5|ERROR: XmDropSiteRegistered not declared in header file Xm/DragDrop.h
    220|100 9 1 16:39:55|FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    A non-alignment between the reference code and its specification is
    under investigation. Thus it is recommended that a Temporary
    Interpretation be granted for this test while it remains subject to review.




    If a change to the specification results from the conclusion of this
    investigation, then this Temporary Interpretation will be converted
    to a Permanent Waiver. Otherwise this Temporary Interpretation will
    be converted to a Temporary Waiver (Minor System Fault).


    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Temporary Interpretation (TIN)
    Review Conclusion
    A Temporary Interpretation is granted.


    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority