Problem Report Number 1954 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.0981 Raised 1996-09-13 08:00 Updated 2003-03-13 08:00 Published 1996-09-26 08:00 Product Standard Transport Service XTI Certification Program The Open Brand certification program Test Suite VST version 4.1.3 Test Identification XTI.os/cots/rcv 6 Problem Summary TSDT4.019 The slave sends 1 byte of normal data with the T_MORE flag set. The suite expects this byte to be transmitted immediately. Our ISO transport implementation, however, enters data transmission only if e... Problem Text
The slave sends 1 byte of normal data with the T_MORE flag set.
The suite expects this byte to be transmitted immediately.
Our ISO transport implementation, however, enters data transmission
only if either the data contain a complete message (T_MORE flag clear)
or data have reached maximum TPDU size.
This behaviour is o.k. with regard to ISO standards; ISO conformance tests
have been passed successfully .
As a consequence, the ETSDU would be sent first; the 1-byte TSDU fragment
would be transmitted afterwards together with the rest of the TSDU.
The suite, however, is waiting for the 1-byte TSDU.Test Output
/tset/XTI.os/cots/rcv/T.rcv 6 Unresolved
Test Information:
Unexpected event on ISO CLASS 2 endpoint
Expected 4 (T_DATA), actual 0 (NO EVENT)Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
It is agreed that this is a Test Suite Deficiency and it is recommended
that a waiver is granted.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion
This is an agreed Test Suite Deficiency.