Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 1907 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 1907.
Report 1907 Actions
Problem Report Number 1907 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0226 Raised 2000-02-10 08:00 Updated 2003-03-13 08:00 Published 2000-02-10 08:00 Product Standard Internationalised System Calls and Libraries Extended V2 (UNIX 98) Certification Program The Open Brand certification program Test Suite VSX4 version 4.4.4 Test Identification ANSI.os/streamio/snprintf 68 Specification System Interfaces and Headers Issue 5 Location in Spec See Problem Text Problem Summary PIN5.006 This is a known grey area in XSH5 for which there is a working group resolution, bwg98-006. The two tests in VSX4: ANSI.os/streamio/snprintf 68 and ANSI.os/streamio/vsnprintf 68 expect the "new" behav... Problem Text
This is a known grey area in XSH5 for which there is a working
group resolution, bwg98-006. The two tests in VSX4:
ANSI.os/streamio/snprintf 68
and
ANSI.os/streamio/vsnprintf 68
expect the "new" behaviour identified in the resolution, and report
the failures shown above on systems which implement snprintf() and
vsnprintf() as per the original XSH5 specification.
A Permanent Interpretation is requested to cover these failures.Test Output
/tset/ANSI.os/streamio/printf/T.snprintf 68 Failed
snprintf(buf, 3, "%s", "abc") returned 2, expected 3
snprintf(buf, 5, "1234567890") returned 4, expected 10
/tset/ANSI.os/streamio/vprintf/T.vsnprintf 68 Failed
vsnprintf(buf, 3, "%s", {"abc"}) returned 2, expected 3
vsnprintf(buf, 5, "1234567890", {}) returned 4, expected 10"Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
It is agreed that a Permanent Interpretation should be granted.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion
A Permanent Interpretation is granted.