Problem Report Number 1883 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.0944 Raised 1998-07-20 08:00 Updated 2003-03-13 08:00 Published 1998-07-20 08:00 Product Standard Internationalised System Calls and Libraries Extended V2 (UNIX 98) Certification Program The Open Brand certification program Test Suite VSX4 version 4.4.3 Test Identification POSIX.os/devclass/cfsetospee 2 Linked Problem Reports TSD4.073, (in, old, system) Problem Summary TSD5.013 This was a common problem for systems dependent on this particular chip architecture for XPG3 branding which continues with XPG4. This is documented as a Known Problem in the VSX release notes. The pr... Problem Text
This was a common problem for systems dependent on this particular
chip architecture for XPG3 branding which continues with XPG4.
This is documented as a Known Problem in the VSX release notes.
The problem is hardware related, certain processors are unable to maintain
high throughput speeds.Test Output
************************************************************************
/tset/POSIX.os/devclass/cfsetospee/T.cfsetospee 2 Failed
Test Description:
If general terminal interface supported:
For each of the baud rates B50, B75, B110, B134, B150, B200, B300,
B600, B1200, B1800, B2400, B4800, B9600, B19200 and B38400 a
successful call to cfsetospeed() followed by a call to tcsetattr()
shall set the output baud rate to the corresponding speed. At
least one of these baud rates shall be supported.
Posix Ref: Component CFSETOSPEED Assertion 7.1.2.7.2-05(C)
Test Strategy:
SET IXON in loop back termios structure SET IXOFF in terminal termios
structure
For each of the specified baud rates:
SET input/output baud rate in terminal structure using
cfsetispeed()/cfsetospeed()
SET terminal information using tcsetattr()
OBTAIN terminal information using tcgetattr()
If input/output baud rate is not set to specified baud rate, baud rate
is not supported
SET input/output baud rate in loop back terminal structure using
cfsetispeed()/cfsetospeed()
SET terminal information using tcsetattr()
OBTAIN terminal information using tcgetattr()
If input/output baud rate is not set to specified baud rate, baud rate
is not supported
If baud rate is supported, CREATE [child process|process pair]
Child: SLEEP using sleep() to allow terminal file to initialise
SET time out.
WRITE data to loop back file using write()
VERIFY that data was written within twice the expected write time
Parent: READ from terminal file using read()
VERIFY that all written data can be read
VERIFY that at least one of the specified baud rates is supported
Test Information:
read error. B38400 test failed
************************************************************************Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
This is an accepted test suite fault and it is recommended that this be
treated as a test suite deficiency.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion
This is an agreed Test Suite Deficiency.