Problem Report Number 1833 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.0910 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1993-11-19 08:00 Product Standard X Window System Applications Interface Certification Program The Open Brand certification program Test Suite VSW version 4.1.1 Test Identification CH07/chngkybrdc 9 Problem Summary TSD4W.00106 Test has 32-bit dependency. Problem Text
This test failed on our system due to incompatible bit representation
from the test suite in 64-bit implementations. We believe that the test
is at fault.
The two changed lines take care of 64 bit longs by considering only bits
corresponding to the "Mask of all leds".
*** ./xtest/tset/CH07/chngkybrdc/chngkybrdc.m Thu Jun 11 17:13:46 1992
--- /usr/projects/x11/vsw_4.1.1/./xtest/tset/CH07/chngkybrdc/chngkybrdc.m
Mon Oct 11 11:07:00 1993
***************
*** 411,420 ****
XGetKeyboardControl(display, &newks);
if (newks.led_mask == onmask)
CHECK;
else {
! report("Led mask was %d, expecting %d",
newks.led_mask, onmask);
FAIL;
}
--- 411,422 ----
XGetKeyboardControl(display, &newks);
+ newks.led_mask = newks.led_mask & NLEDMASK;
+ onmask = onmask & NLEDMASK ;
if (newks.led_mask == onmask)
CHECK;
else {
! report("Led mask was %lx, expecting %lx",
newks.led_mask, onmask);
FAIL;
}
Test Output
/tset/CH07/chngkybrdc/Test 9 Failed
Test Description:
If LED s are supported: When both KBLed and KBLedMode are
specified, then the state of the LED specified by led is
changed to the state specified by led_mode.
Test Strategy:
Set value_mask to KBLed | KBLedMode.
Set led value.
Set led_mode value.
Call XChangeKeyboardControl.
Get new keyboard state.
Verify that change occurred.
Test Information:
Led mask was -2146959345, expecting -2146959345Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
This is agreed to be a test suite deficiency.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion
This is an agreed Test Suite Deficiency.