HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 1790 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 1790.


Report 1790 Actions


    Problem Report Number 1790
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0867
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1998-12-11 08:00
    Product Standard X Window System Applications Interface
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.0.1
    Test Identification Xlib14/fltrevnt/Test/XFilterEvent-1 1
    Problem Summary TSD4W.00159 This test may fail due to using a non-portable key code to stimulate an event.
    Problem Text
    For the test Xlib14-XFilterEvent-1, we are getting a similar result
    as in the waiver TSD4W.00150. However, the waiver says explicitly
    keycode 0x42 which is not the problem in our case. The tests
    generate a failure in keycodes 0x0a (10) and 0x0d (13) which on our
    systems are invalid keycodes (min for us is 15).

    Can we apply the waiver TSD4W.00150 to the failure we are seeing for
    Xlib14-XFilterEvent-1?
    Test Output
    10|539 /tset/Xlib14/fltrevnt/Test 18:59:53|TC Start, scenario ref 1093-0
    15|539 3.1-lite 1|TCM Start
    400|539 1 1 18:59:58|IC Start
    200|539 1 18:59:58|TP Start
    520|539 1 00008501 1 1|VSW5TESTSUITE PURPOSE 1
    520|539 1 00008501 1 2|Assertion XFilterEvent-1.(D)
    520|539 1 00008501 1 3|If the implementation is X11R5 or later: A call to
    520|539 1 00008501 1 4|XFilterEvent shall give the input method server a chance
    to
    520|539 1 00008501 1 5|process an event if a filter is registered for the event
    for
    520|539 1 00008501 1 6|a given window, win.
    520|539 1 00008501 1 7|Reason for omission: There is no known reliable test method for this assertion
    520|539 1 00008501 1 8|METH: Read a set of stimuli from a stimulus file and compare actual response
    520|539 1 00008501 1 9|METH: to the expected responses.
    520|539 1 00008501 1 10|REPORT: Unexpected error BadValue
    520|539 1 00008501 1 11|REPORT: BadValue (integer parameter out of range for operation)
    520|539 1 00008501 1 12|REPORT: Protocol request was UNDEFINED (major=134, minor=2)
    520|539 1 00008501 1 13|REPORT: Unexpected Xlib error
    520|539 1 00008501 1 14|REPORT: Unexpected error BadValue
    520|539 1 00008501 1 15|REPORT: BadValue (integer parameter out of range for operation)
    520|539 1 00008501 1 16|REPORT: Protocol request was UNDEFINED (major=134, minor=2)
    520|539 1 00008501 1 17|REPORT: Unexpected Xlib error
    220|539 1 2 19:00:00|UNRESOLVED
    410|539 1 1 19:00:00|IC End

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    We agree this is a test suite deficiency in the test
    suite version(s) listed.

    This assertion has been labeled as UNTESTABLE in later versions
    of the test suite.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.

    Problem Reporting System Options:

     

    Back   