Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 1779 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 1779.
Report 1779 Actions
Problem Report Number 1779 Submitter's Classification Specification problem State Resolved Resolution Temporary Interpretation (TIN) Problem Resolution ID TIN.X.0078 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1998-03-19 08:00 Product Standard Window System Application Interface V2 Certification Program The Open Brand certification program Test Suite VSW version 5.0.0 Test Identification Xlib14/openim 1 Specification Window Management (X11R5): Xlib - C Language Binding Location in Spec See Problem Text Problem Summary TIN4W.00004 This submitter claims the test may fail because of a difference between the reference code and the specification. Problem Text
A non-alignment between the reference code and its specification is under
investigation (cf vsw_req #149). Thus it is recommended that a Temporary
Interpretation be granted for this test while it remains subject to review.
If a change to the specification results from the conclusion of this
investigation, then this Temporary Interpretation will be converted
to a Permanent Waiver. Otherwise this Temporary Interpretation will
be converted to a Temporary Waiver (Minor System Fault).Test Output
SECTION: Xlib14
TEST CASE: XSetICFocus
TEST PURPOSE #1
Assertion XSetICFocus-1.(C)
If the implementation is X11R5 or later: A call to
XSetICFocus shall set input context focus.
PREP: Create a window for test.
TEST: XSetICFocus sets input context focus.
WARNING: No input method supported
UNRESOLVEDReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
A temporary interpretation is recommended.
A non-alignment between the reference code and its specification
is under investigation. Thus it is recommended that a Temporary
Interpretation be granted for this test while it remains subject
to review. If a change to the specification results from the
conclusion of this investigation, then this Temporary
Interpretation will be converted to a Permanent Waiver.
Otherwise this Temporary Interpretation will be converted to a
Temporary Waiver (Minor System Fault).
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Temporary Interpretation (TIN) Review Conclusion
A Temporary Interpretation is granted.
Problem Reporting System Options: