HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 1778 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 1778.


Report 1778 Actions


    Problem Report Number 1778
    Submitter's Classification Minor System Fault
    State Resolved
    Resolution Temporary Interpretation (TIN)
    Problem Resolution ID TIN.X.0077
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1998-03-19 08:00
    Product Standard Window System Application Interface V2
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.0.0
    Test Identification XtC/tpending 1
    Specification Window Management (X11R5): X Toolkit Intrinsics
    Location in Spec See Problem Text
    Problem Summary TIN4W.00005 This submitter claims the test may fail because of a difference between the reference code and the specification.
    Problem Text
    Please note: When we tested this with Xt R11 6.3 it passed.
    With my current original Xopen source using Xt R11 6.4 it fails.
    This bug (if it is one) will be corrected in some future
    fix-tracker which we will include into our system.
    R11 6.4 corrected 7 FAILs/UNRESOLVEDs but added 2 new ones.
    For one I found a TSD4W. But for this problem I found none.
    One cannot expect us to check each fix-tracker until we find one
    which has the least FAILs. There will always be some bugs in the system.

    Test Output
    SECTION: XtC

    TEST CASE:XtPending

    TEST PURPOSE #1
    Assertion XtPending-1.(A)
    When the calling process has at least one pending event
    from the X server or an alternate source a successful call
    to Boolean XtPending() shall return a nonzero value.
    PREP: Initialize toolkit, Open display and Create topLevel root widget
    PREP: Register timeout
    PREP: Create windows for widgets and map them
    TEST: XtPending will return correct mask
    ERROR: XtPending says event is pending but XtPeekEvent says no
    t
    ERROR: Expected reports of timeout of 1, Received 0
    ERROR: Expected reports of keypresses of 1, Received 0
    FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    A temporary interpretation is recommended.

    A non-alignment between the reference code and its specification
    is under investigation. Thus it is recommended that a Temporary
    Interpretation be granted for this test while it remains subject
    to review. If a change to the specification results from the
    conclusion of this investigation, then this Temporary
    Interpretation will be converted to a Permanent Waiver.
    Otherwise this Temporary Interpretation will be converted to a
    Temporary Waiver (Minor System Fault).

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Temporary Interpretation (TIN)
    Review Conclusion
    A Temporary Interpretation is granted.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority