HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 1740 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 1740.


Report 1740 Actions


    Problem Report Number 1740
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Rejected (REJ)
    Problem Resolution ID REJ.X.0523
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published null
    Product Standard Window System Application Interface V2
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.0.0
    Test Identification Xt11/tvagtares 3
    Problem Summary PG4W.00061 This IR does includes journal output but no reasons for interpretation.
    Problem Text

    Test Output
    SECTION: Xt11

    TEST CASE: XtVaGetApplicationResources

    TEST PURPOSE #3
    10|2554 /tset/Xt11/tvagtares/Test 18:41:47|TC Start, scenario ref 1730-0
    VSW5TESTSUITE PURPOSE 3
    Assertion XtVaGetApplicationResources-3.(A)
    On a call to void XtVaGetApplicationResources(w, base,
    resources, num_resources,....) when the name XtVaTypedArg
    is specified in place of a resource name in the variable
    argument list it shall interpret the four arguments
    following this argument as a name/type/value/size tuple.
    PREP: Initialize toolkit, Open display and Create topLevel root widget
    PREP: Create windows for widgets and map them
    TEST: Retrieve resource values from arg list
    WARNING: ****************************************************************
    WARNING: An Xt warning occured during a toolkit call:
    WARNING: Unable to find type of resource for conversion
    WARNING: ****************************************************************
    TEST: Retrieved resource value
    ERROR: Expected "label value", received "XtDefaultLabel"
    FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    We recommend this request be refused.

    IRs must provide reasoning for why an interpretation is needed for the
    journal output provided. If the test is believed to be in error or
    the standard is unclear or gray, sufficient reasoning and rationale
    must be provided to support the request.


    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Rejected (REJ)
    Review Conclusion
    This request is refused.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority