Problem Report Number 1694 Submitter's Classification Specification problem State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0067 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1998-04-15 08:00 Expiry Date null Product Standard Window System Application Interface V2 Certification Program The Open Brand certification program Test Suite VSW version 5.0.0 Test Identification Xt11/XtCvtStringToFloat 4 Problem Summary MSF4W.00013 A test failure due to a non-alignment between the reference code and its specification prior to X11R6.4. Problem Text
The reference implementation (i.e. The X11 code provided by TOG) being
tested is not in line with the standard specification for this X11
function as defined in the "X Toolkit Intrinsics - C Language
Interface".
The assertion being tested is in line with the standard specification
but the behavior of this function is not in line with the specification.
Either the X11 reference implementation is at fault, or the
Specification needs to be aligned with the reference implemenation. It
is our understanding that X11R6.1 is no longer supported by TOG,
hence we request this waiver be granted a Permanent Interpretation.
Section 9.6.2 (New Resource Converters) of the Xt spec states:
If the conversion cannot be performed because of an improper
source value, a warning message should also be issued with
XtAppWarningMsg.
The function, XtCvtStringToFloat does not always call XtAppWarningMsg
when a failure occurs and thus the vsw5 test purpose fails.Test Output
520|2581 4 6004 1 1|VSW5TESTSUITE PURPOSE 4
520|2581 4 6004 1 2|Assertion XtCvtStringToFloat-4.(A)
520|2581 4 6004 1 3|If the implementation is X11R5 or later: A call to Boolean
520|2581 4 6004 1 4|XtCvtStringToFloat(display, args, num_args, from, to,
520|2581 4 6004 1 5|converter_data) when the conversion is not performed due to
520|2581 4 6004 1 6|an improper value specified in from shall issue a warning
520|2581 4 6004 1 7|message and return False.
520|2581 4 5976 1 1|PREP: Initialize toolkit, Open display and Create topLevel
root widget
520|2581 4 5976 1 2|PREP: Create windows for widgets and map them
520|2581 4 5976 1 3|PREP: Get display
520|2581 4 5976 1 4|PREP: Set up required conversion args
520|2581 4 5976 1 5|TEST: Conversion fails
520|2581 4 5976 1 6|ERROR: Expected XtCvtStringToFloat return value of
0, Received 1
520|2581 4 5964 2 1|TEST: Warning handler is called
520|2581 4 5964 2 2|ERROR: Expected calls to warning handler count of 1,
Received 0
220|2581 4 1 15:51:14|FAIL
410|2581 4 1 15:51:14|IC EndReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
A Minor System Fault waiver is recommended.
Open Group procedures specify that when there is a version of the
reference code available from The Open Group that aligns with the
specification for a reported defect that an MSF is issued. This
failure is XPT defect XWSog08568 which is corrected in X11R6.4.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion
A Temporary Waiver is granted.