Report 1694 Actions


    Problem Report Number 1694
    Submitter's Classification Specification problem
    State Resolved
    Resolution Minor System Fault (MSF)
    Problem Resolution ID MSF.X.0067
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1998-04-15 08:00
    Expiry Date null
    Product Standard Window System Application Interface V2
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.0.0
    Test Identification Xt11/XtCvtStringToFloat 4
    Problem Summary MSF4W.00013 A test failure due to a non-alignment between the reference code and its specification prior to X11R6.4.
    Problem Text
    The reference implementation (i.e. The X11 code provided by TOG) being
    tested is not in line with the standard specification for this X11
    function as defined in the "X Toolkit Intrinsics - C Language
    Interface".

    The assertion being tested is in line with the standard specification
    but the behavior of this function is not in line with the specification.

    Either the X11 reference implementation is at fault, or the
    Specification needs to be aligned with the reference implemenation. It
    is our understanding that X11R6.1 is no longer supported by TOG,
    hence we request this waiver be granted a Permanent Interpretation.

    Section 9.6.2 (New Resource Converters) of the Xt spec states:

    If the conversion cannot be performed because of an improper
    source value, a warning message should also be issued with
    XtAppWarningMsg.

    The function, XtCvtStringToFloat does not always call XtAppWarningMsg
    when a failure occurs and thus the vsw5 test purpose fails.
    Test Output
    520|2581 4 6004 1 1|VSW5TESTSUITE PURPOSE 4
    520|2581 4 6004 1 2|Assertion XtCvtStringToFloat-4.(A)
    520|2581 4 6004 1 3|If the implementation is X11R5 or later: A call to Boolean
    520|2581 4 6004 1 4|XtCvtStringToFloat(display, args, num_args, from, to,
    520|2581 4 6004 1 5|converter_data) when the conversion is not performed due to
    520|2581 4 6004 1 6|an improper value specified in from shall issue a warning
    520|2581 4 6004 1 7|message and return False.
    520|2581 4 5976 1 1|PREP: Initialize toolkit, Open display and Create topLevel
    root widget
    520|2581 4 5976 1 2|PREP: Create windows for widgets and map them
    520|2581 4 5976 1 3|PREP: Get display
    520|2581 4 5976 1 4|PREP: Set up required conversion args
    520|2581 4 5976 1 5|TEST: Conversion fails
    520|2581 4 5976 1 6|ERROR: Expected XtCvtStringToFloat return value of
    0, Received 1
    520|2581 4 5964 2 1|TEST: Warning handler is called
    520|2581 4 5964 2 2|ERROR: Expected calls to warning handler count of 1,
    Received 0
    220|2581 4 1 15:51:14|FAIL
    410|2581 4 1 15:51:14|IC End

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    A Minor System Fault waiver is recommended.

    Open Group procedures specify that when there is a version of the
    reference code available from The Open Group that aligns with the
    specification for a reported defect that an MSF is issued. This
    failure is XPT defect XWSog08568 which is corrected in X11R6.4.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Minor System Fault (MSF)
    Review Conclusion
    A Temporary Waiver is granted.