HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 1687 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 1687.


Report 1687 Actions


    Problem Report Number 1687
    Submitter's Classification Minor System Fault
    State Resolved
    Resolution Minor System Fault (MSF)
    Problem Resolution ID MSF.X.0060
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1998-07-10 08:00
    Expiry Date 1999-04-15
    Product Standard X Window System Display
    Certification Program The Open Brand certification program
    Test Suite VSW version 5.0.1
    Test Identification Xt11/XtCvtStringToTranslationTable 4
    Problem Summary MSF4W.00020 Test failure due to a non-alignment between the reference code and its specification prior to X11R6.4.
    Problem Text
    As per MSF4W.00012.
    (We are using X11R6.0)
    Test Output
    TEST CASE: XtCvtStringToTranslationTable

    TEST PURPOSE #4
    Assertion XtCvtStringToTranslationTable-4.(A)
    If the implementation is X11R5 or later: A call to Boolean
    XtCvtStringToTranslationTable(display, args, num_args, from,
    to, converter_data) when the conversion is not performed due
    to an improper value specified in from shall issue a warning
    message and return False.
    PREP: Initialize toolkit, Open display and Create topLevel root widget
    PREP: Set Warning Message Handler
    PREP: Create windows for widgets and map them
    PREP: Get display
    PREP: Set up required conversion args
    TEST: Conversion fails
    ERROR: Expected XtCvtStringToTranslationTable return value of 0, Received 1
    TEST: Warning message was generated
    4 FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    A Minor System Fault waiver is recommended as per MSF4W.00012.

    Open Group procedures specify that when there is a version of the
    reference code available from The Open Group that aligns with the
    specification for a reported defect that an MSF is issued. This
    failure is XPT defect XWSog08568 which is corrected in X11R6.4.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Minor System Fault (MSF)
    Review Conclusion
    A Temporary Waiver is granted.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority