HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 1537 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 1537.


Report 1537 Actions


    Problem Report Number 1537
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0819
    Raised 2000-02-24 08:00
    Updated 2003-03-13 08:00
    Published 2000-02-25 08:00
    Product Standard Internationalised System Calls and Libraries Extended V2 (UNIX 98)
    Certification Program The Open Brand certification program
    Test Suite VSU version 5.0.4
    Test Identification headers/signal.h 105
    Problem Summary TSD4U.00280 The test incorrectly reports sigwait as an invalid symbol for signal.h
    Problem Text
    This test is erroneously flagging 'sigwait' as an invalid symbol.
    It is valid according to signal.h header specifications in
    CAE Specifications, Iss 5 Vol 2.

    Test Output

    TEST PURPOSE #105
    The inclusion of signal.h with _XOPEN_SOURCE defined
    with the value 500 shall only define or declare
    identifiers with external linkage, macros, and
    identifiers with file scope specified in the signal.h
    header file section; identifiers prefixed with 'sa_',
    'si_', 'ss_', 'sv_', 'SIG[A-Z]', 'SIG_[A-Z]', 'SI_',
    'sigev_', 'SIGEV_', or 'sival_'; macros prefixed with
    'SA_', 'SIG_[0-9a-z]', 'BUS_', 'CLD_', 'FPE_', 'ILL_',
    'POLL_', 'SEGV_', 'SI_', 'SS_', 'SV_', 'TRAP_',
    'sigev_', 'SIGEV_', or 'sival_'; identifiers and
    macros suffixed with '_t'; and identifiers and macros
    prefixed with underscore and either an alphanumeric
    character or another underscore.
    ERROR: Invalid symbol name 'sigwait'
    105 FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    This is accepted as a fault in the test suite.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.