Problem Report Number 1276 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.0558 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1998-10-02 08:00 Product Standard Internationalised Terminal Interfaces Certification Program The Open Brand certification program Test Suite VSU version 5.0.2 Test Identification headers/hxcurses 934 Problem Summary TSD4U.00260 This test will fail on implementations which use values for A_ attributes which will not fit in an attr_t. Problem Text
This is another instance of the behavior described in TSD4U.00253.Test Output
200|743 2 20:34:02|TP Start
520|743 2 25417 1 1|SPEC1170TESTSUITE CASE 934
520|743 2 25417 1 2|The values defined in curses.h for attributes stored in
520|743 2 25417 1 3|objects of type chtype shall be distinct when
520|743 2 25417 1 4|_XOPEN_CURSES is defined and the application sets
520|743 2 25417 1 5|defines _XOPEN_SOURCE with the value 500.
520|743 2 25417 1 6|TEST: Uniqueness
520|743 2 25417 1 7|ERROR: Value for A_ALTCHARSET (0) equal to value for A_BLINK.
520|743 2 25417 1 8|ERROR: Value for A_ALTCHARSET (0) equal to value for A_BOLD.
520|743 2 25417 1 9|ERROR: Value for A_ALTCHARSET (0) equal to value for A_DIM.
520|743 2 25417 1 10|ERROR: Value for A_ALTCHARSET (0) equal to value for A_INVIS.
520|743 2 25417 1 11|ERROR: Value for A_ALTCHARSET (0) equal to value for A_PROTECT.
520|743 2 25417 1 12|ERROR: Value for A_ALTCHARSET (0) equal to value for A_REVERSE.
520|743 2 25417 1 13|ERROR: Value for A_ALTCHARSET (0) equal to value for A_STA DOUT.
520|743 2 25417 1 14|ERROR: Value for A_ALTCHARSET (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 15|ERROR: Value for A_BLINK (0) equal to value for A_BOLD.
520|743 2 25417 1 16|ERROR: Value for A_BLINK (0) equal to value for A_DIM.
520|743 2 25417 1 17|ERROR: Value for A_BLINK (0) equal to value for A_INVIS.
520|743 2 25417 1 18|ERROR: Value for A_BLINK (0) equal to value for A_PROTECT.
520|743 2 25417 1 19|ERROR: Value for A_BLINK (0) equal to value for A_REVERSE.
520|743 2 25417 1 20|ERROR: Value for A_BLINK (0) equal to value for A_STANDOUT.
520|743 2 25417 1 21|ERROR: Value for A_BLINK (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 22|ERROR: Value for A_BOLD (0) equal to value for A_DIM.
520|743 2 25417 1 23|ERROR: Value for A_BOLD (0) equal to value for A_INVIS.
520|743 2 25417 1 24|ERROR: Value for A_BOLD (0) equal to value for A_PROTECT.
520|743 2 25417 1 25|ERROR: Value for A_BOLD (0) equal to value for A_REVERSE.
520|743 2 25417 1 26|ERROR: Value for A_BOLD (0) equal to value for A_STANDOUT.
520|743 2 25417 1 27|ERROR: Value for A_BOLD (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 28|ERROR: Value for A_DIM (0) equal to value for A_INVIS.
520|743 2 25417 1 29|ERROR: Value for A_DIM (0) equal to value for A_PROTECT.
520|743 2 25417 1 30|ERROR: Value for A_DIM (0) equal to value for A_REVERSE.
520|743 2 25417 1 31|ERROR: Value for A_DIM (0) equal to value for A_STANDOUT.
520|743 2 25417 1 32|ERROR: Value for A_DIM (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 33|ERROR: Value for A_INVIS (0) equal to value for A_PROTECT.
520|743 2 25417 1 34|ERROR: Value for A_INVIS (0) equal to value for A_REVERSE.
520|743 2 25417 1 35|ERROR: Value for A_INVIS (0) equal to value for A_STANDOUT.
520|743 2 25417 1 36|ERROR: Value for A_INVIS (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 37|ERROR: Value for A_PROTECT (0) equal to value for A_REVERSE.
520|743 2 25417 1 38|ERROR: Value for A_PROTECT (0) equal to value for A_STANDOUT.
520|743 2 25417 1 39|ERROR: Value for A_PROTECT (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 40|ERROR: Value for A_REVERSE (0) equal to value for A_STANDOUT.
520|743 2 25417 1 41|ERROR: Value for A_REVERSE (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 42|ERROR: Value for A_STANDOUT (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 22|ERROR: Value for A_BOLD (0) equal to value for A_DIM.
520|743 2 25417 1 23|ERROR: Value for A_BOLD (0) equal to value for A_INVIS.
520|743 2 25417 1 24|ERROR: Value for A_BOLD (0) equal to value for A_PROTECT.
520|743 2 25417 1 25|ERROR: Value for A_BOLD (0) equal to value for A_REVERSE.
520|743 2 25417 1 26|ERROR: Value for A_BOLD (0) equal to value for A_STANDOUT.
520|743 2 25417 1 27|ERROR: Value for A_BOLD (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 28|ERROR: Value for A_DIM (0) equal to value for A_INVIS.
520|743 2 25417 1 29|ERROR: Value for A_DIM (0) equal to value for A_PROTECT.
520|743 2 25417 1 30|ERROR: Value for A_DIM (0) equal to value for A_REVERSE.
520|743 2 25417 1 31|ERROR: Value for A_DIM (0) equal to value for A_STANDOUT.
520|743 2 25417 1 32|ERROR: Value for A_DIM (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 33|ERROR: Value for A_INVIS (0) equal to value for A_PROTECT.
520|743 2 25417 1 34|ERROR: Value for A_INVIS (0) equal to value for A_REVERSE.
520|743 2 25417 1 35|ERROR: Value for A_INVIS (0) equal to value for A_STANDOUT.
520|743 2 25417 1 36|ERROR: Value for A_INVIS (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 37|ERROR: Value for A_PROTECT (0) equal to value for A_REVERSE.
520|743 2 25417 1 38|ERROR: Value for A_PROTECT (0) equal to value for A_STANDOUT.
520|743 2 25417 1 39|ERROR: Value for A_PROTECT (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 40|ERROR: Value for A_REVERSE (0) equal to value for A_STANDOUT.
520|743 2 25417 1 41|ERROR: Value for A_REVERSE (0) equal to value for A_UNDERLINE.
520|743 2 25417 1 42|ERROR: Value for A_STANDOUT (0) equal to value for A_UNDERL
INE.
220|743 2 1 20:34:02|FAIL
410|743 934 1 20:34:02|IC End
Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
We agree this is a test suite deficiency in the test
suite version(s) listed.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion
This is an agreed Test Suite Deficiency.