Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 1031 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 1031.
Report 1031 Actions
Problem Report Number 1031 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0131 Raised 2003-01-14 08:00 Updated 2003-03-13 08:00 Published 2003-01-14 08:00 Product Standard Commands and Utilities V3 (UNIX 98) Certification Program The Open Brand certification program Test Suite VSC version 5.1.3 Test Identification POSIX.upe/ex 1013,1014 Specification Commands and Utilities Issue 5 Location in Spec See Problem Text Linked Problem Reports PIN4C.00016, (in, old, system) Problem Summary PIN4C.00067 This test may fail on implementations that implement historical ed compatible behavior. Problem Text
The UNIX95 grey area identified in PIN4C.00016 still exists in SUSv2, so
an equivalent PIN should be issued for UNIX98.Test Output
520|1 1 15471 1 1|Assertion #1013 (C): Test edcompatible set option with c/g
520|1 1 15471 1 11|Standard output isn't the same as file 'ex_exp_1'
520|1 1 15471 1 12|diff of "out.stdout" and "ex_exp_1"
520|1 1 15471 1 13|*** out.stdout Fri Jan 10 14:42:22 1997
520|1 1 15471 1 14|--- ex_exp_1 Fri Jan 10 14:41:49 1997
520|1 1 15471 1 15|***************
520|1 1 15471 1 16|*** 1,2 ****
520|1 1 15471 1 17|! hXrX Ys a filX
520|1 1 15471 1 18| and anothXr lYnX
520|1 1 15471 1 19|--- 1,2 ----
520|1 1 15471 1 20|! hXrX Ys a fYlX
520|1 1 15471 1 21| and anothXr lYnX
220|1 1 1 14:42:25|FAIL
520|1 1 15739 1 1|Assertion #1014 (C): Test edcompatible set option without
c/g
520|1 1 15739 1 11|Standard output isn't the same as file 'ex_exp_1'
520|1 1 15739 1 12|diff of "out.stdout" and "ex_exp_1"
520|1 1 15739 1 13|*** out.stdout Fri Jan 10 14:43:23 1997
520|1 1 15739 1 14|--- ex_exp_1 Fri Jan 10 14:42:51 1997
520|1 1 15739 1 15|***************
520|1 1 15739 1 16|*** 1,2 ****
520|1 1 15739 1 17| hXrX is Z filX
520|1 1 15739 1 18|! Znd ZnothXr linX
520|1 1 15739 1 19|--- 1,2 ----
520|1 1 15739 1 20| hXrX is Z filX
520|1 1 15739 1 21|! Znd anothXr linX
220|1 1 1 14:43:26|FAILReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
A Permanent Interpretation is recommended.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion
A Permanent Interpretation is granted.