Report 1022 Actions


    Problem Report Number 1022
    Submitter's Classification Specification problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0122
    Raised 2001-03-29 08:00
    Updated 2003-03-13 08:00
    Published 2001-03-30 08:00
    Product Standard Commands and Utilities V3 (UNIX 98)
    Certification Program The Open Brand certification program
    Test Suite VSC version 5.1.1
    Test Identification POSIX.cmd/bc 139,141,142,144
    Specification Commands and Utilities Issue 5
    Location in Spec See Problem Text
    Linked Problem Reports PIN4C.00017, (in, old, system)
    Problem Summary PIN4C.00058 tests should all scale of some calculations to be either 0 or 20
    Problem Text
    The scale of the result of bc was recently the subject of an
    interpretation (PASC 1003.2-92 #96) with the resolution being
    the standard was unclear on this matter and was being referred
    to the sponsor. The wording has been changed in P1003.2b/D11.
    Test Output
    Assertion #139 (A): check sin
    Note: The behavior associated with this assertion is currently
    the subject of an IEEE POSIX.2 interpretation request and may
    change in a future revision of POSIX.2.
    Standard output isn't the same as file 'bc_eso_139_1'
    diff of "out.stdout" and "bc_eso_139_1":
    *** out.stdout Tue Aug 1 19:54:49 1995
    --- bc_eso_139_1 Tue Aug 1 19:54:49 1995
    ***************
    *** 1,5 ****
    0
    ! 20
    1.68294
    20
    1.68294
    --- 1,5 ----
    0
    ! 0
    1.68294
    20
    1.68294
    Assertion Result: FAIL

    Assertion #141 (A): check arctanngent
    Note: The behavior associated with this assertion is currently
    the subject of an IEEE POSIX.2 interpretation request and may
    change in a future revision of POSIX.2.
    Standard output isn't the same as file 'bc_eso_141_1'
    diff of "out.stdout" and "bc_eso_141_1":
    *** out.stdout Tue Aug 1 19:55:08 1995
    --- bc_eso_141_1 Tue Aug 1 19:55:08 1995
    ***************
    *** 1,5 ****
    0
    ! 20
    3.14159
    20
    3.14159
    --- 1,5 ----
    0
    ! 0
    3.14159
    20
    3.14159
    Assertion Result: FAIL

    Assertion #142 (A): check log
    Note: The behavior associated with this assertion is currently
    the subject of an IEEE POSIX.2 interpretation request and may
    change in a future revision of POSIX.2.
    Standard output isn't the same as file 'bc_eso_142_1'
    diff of "out.stdout" and "bc_eso_142_1":
    *** out.stdout Tue Aug 1 19:55:21 1995
    --- bc_eso_142_1 Tue Aug 1 19:55:21 1995
    ***************
    *** 1,5 ****
    0
    ! 20
    2.30259
    20
    2.30259
    --- 1,5 ----
    0
    ! 0
    2.30259
    20
    2.30259
    Assertion Result: FAIL

    Assertion #144 (A): check bessel
    Note: The behavior associated with this assertion is currently
    the subject of an IEEE POSIX.2 interpretation request and may
    change in a future revision of POSIX.2.
    Standard output isn't the same as file 'bc_eso_144_1'
    diff of "out.stdout" and "bc_eso_144_1":
    *** out.stdout Tue Aug 1 19:55:50 1995
    --- bc_eso_144_1 Tue Aug 1 19:55:50 1995
    ***************
    *** 1,5 ****
    0
    ! 20
    1.57672
    20
    1.57672
    --- 1,5 ----
    0
    ! 0
    1.57672
    20
    1.57672
    Assertion Result: FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    A Permanent Interpretation is recommended.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion
    A Permanent Interpretation is granted.