Problem Report Number 1020 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0120 Raised 2001-03-29 08:00 Updated 2003-03-13 08:00 Published 2001-03-30 08:00 Product Standard Commands and Utilities V3 (UNIX 98) Certification Program The Open Brand certification program Test Suite VSC version 5.1.1 Test Identification POSIX.upe/patch 13 Specification Commands and Utilities Issue 5 Location in Spec See Problem Text Linked Problem Reports PIN4C.00022, (in, old, system) Problem Summary PIN4C.00056 Test of -D option should allow #ifndef use. Problem Text
Historically, patch's -D option has used both #ifdef and #ifndef
constructs. The IEEE interpretation PASC 1003.2-92 #69 states
that POSIX.2's failure to allow the use of both constructs is
a defect in the standard.
Our implementation conforms to the draft POSIX.2b standard which
more accurately describes historical behaviour in this area.
Since this area of the specification is subject to change, we
request a temporary interpretation allowing historical practice.Test Output
200|46 1 17:53:03|TP Start
520|46 1 462094346 1 1|Assertion #13 (C):
520|46 1 462094346 1 1|Note: The behavior associated with this assertion is expected
520|46 1 462094346 1 2|to change in a future revision of POSIX.2.
520|46 1 462094346 1 3|-TC13- Output differs from the expected output
220|46 1 1 17:53:12|FAILReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
A Permanent Interpretation is recommended.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion