Problem Report Number 0956 Submitter's Classification Test Suite problem State Resolved Resolution Test Suite Deficiency (TSD) Problem Resolution ID TSD.X.0471 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1995-08-24 08:00 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.4 Test Identification POSIX.cmd/pax 1029 1038 Problem Summary TSD4C.00038 The tests may fail on non-ASCII systems. Problem Text
The tests are failing on non-ASCII systems because native() is
not being called before checking the mode or typeflag field.Test Output
200|1 1 12:44:16|TP Start
520|1 1 23115 1 1|Assertion #1029 (A):
520|1 1 23115 1 1|expected '777', got 'Field is too short'
220|1 1 1 12:44:19|FAIL
200|4 1 12:44:35|TP Start
520|4 1 23395 1 1|Assertion #1038 (A):
520|4 1 23395 1 1|Checking type 0
520|4 1 23395 1 2|Checking type 1
520|4 1 23395 1 3|Checking type 2
520|4 1 23395 1 4|Checking type 3
520|4 1 23395 1 5|Checking type 4
520|4 1 23395 1 6|Checking type 5
520|4 1 23395 1 7|Checking type 6
520|4 1 23395 1 8|Got type 0 for file pax_fifo_1038, expected 6
220|4 1 1 12:44:43|FAILReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
We agree this is a test suite deficiency in the test
suite version(s) listed.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Test Suite Deficiency (TSD) Review Conclusion
This is an agreed Test Suite Deficiency.