HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0770 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0770.


Report 0770 Actions


    Problem Report Number 0770
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0285
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published 1999-03-30 08:00
    Product Standard Commands and Utilities V3 (UNIX 98)
    Certification Program The Open Brand certification program
    Test Suite VSC version 5.0.2
    Test Identification POSIX.cmd/ipcrm 1008
    Problem Summary TSD4C.00226 The test case begins by saving ipcs state and create needed message queues, shared memeory segments and semaphore sets. It then removes all of the semaphore sets, message queues, and shared memory seg...
    Problem Text

    The test case begins by saving ipcs state and create needed message queues,
    shared memeory segments and semaphore sets. It then removes all of the semaphore
    sets, message queues, and shared memory segments created and compares the resulting
    ipcs state with the one previously saved. It the repeats this process except
    deleting the message queues, shared memory segments and semaphore sets in different
    order.

    This can create a problem if VSC 5.0.2 was run on a system right
    after a reboot. According to CAE Specification, Commands and Utilities,
    Issue 5, page 406, "If the corresponding facility is not installed or has not been used
    since the last reboot, then the report is written out in the format:

    "%s facility not in system.\n", <facility>"

    Hence, running a diff on the two ipcs output may report an error.
    This test case should not assume that the message queue facility
    has already been used.

    We do realize that our ipcs output "Message Queue facility inactive"
    is incorrect. We are in the process of changing it.


    Test Output

    XOPEN.cmd/ipcrm/tp1008
    *******************************************************************************
    520|1 1 20275 1 1|Assertion #1008 (A): Options can be provided in any order
    520|1 1 20275 1 11|SETUP: save ipcs state
    520|1 1 20275 1 12|SETUP: create ipcs
    520|1 1 20275 1 13|TEST: ipcrm -q msgid -m shmid -s semid -Q msg_key2 -M shm_ke
    520|1 1 20275 1 14| <LC> y2 -S shm_key2
    520|1 1 20275 1 15|VERIFY: ipcs state is back to the original state
    520|1 1 20275 1 16|Expected exit code = 0; Received 1
    520|1 1 20275 1 17|Standard output isn't empty
    520|1 1 20275 1 18|Contents of out.stdout:
    520|1 1 20275 1 19|1a2
    520|1 1 20275 1 20|> Message Queue facility inactive.
    520|1 1 20275 1 21|3d3
    520|1 1 20275 1 22|< Message Queues:
    520|1 1 20275 1 23|SETUP: create ipcs
    520|1 1 20275 1 24|TEST: ipcrm -Q msg_key2 -M shm_key2 -S shm_key2 -q msgid -m
    520|1 1 20275 1 25| <LC> shmid -s semid
    520|1 1 20275 1 26|VERIFY: ipcs state is back to the original state
    520|1 1 20275 1 27|Expected exit code = 0; Received 1
    520|1 1 20275 1 28|Standard output isn't empty
    520|1 1 20275 1 29|Contents of out.stdout:
    520|1 1 20275 1 30|1a2
    520|1 1 20275 1 31|> Message Queue facility inactive.
    520|1 1 20275 1 32|3d3
    520|1 1 20275 1 33|< Message Queues:
    220|1 1 1 10:01:48|FAIL
    410|1 1008 1 10:01:48|IC End
    400|1 1009 1 10:01:48|IC Start
    *******************************************************************************

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    We agree this is a test suite deficiency in the test
    suite version(s) listed.

    Note that the message, "Message Queue facility inactive" is not valid.
    This TSD recommendation is only valid, if the error message is
    "Message Queue facility not in system.\n"

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority