Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0756 Details Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0756.
Report 0756 Actions
Problem Report Number 0756 Submitter's Classification Specification problem State Resolved Resolution Temporary Interpretation (TIN) Problem Resolution ID TIN.X.0047 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1995-09-20 08:00 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.4 Test Identification POSIX.upe/ex 202 Specification Commands and Utilities Issue 4 Version 2 Location in Spec See Problem Text Problem Summary TIN4C.00014 This test may fail on implementations that position the current line indicator on the last line moved after a move command. Problem Text
This test may fail on implementations that position the current
line indicator on the last line moved after a move command.
This test checks to see that the current line indicator will be
set to the first of the lines moved after a move command takes
place. This is the behavior currently mandated by the ex spec.
POSIX 1003.2b/D11 has respecified this behavior such that the
current line indicator will be set to the last of the lines moved
after a move.
Our implementation follows the .2b mandated behavior and therefore
fails the test.
We believe the X/Open spec should be relaigned to with .2b and
the test should allow this behavior.Test Output
Assertion #202 (C): setting of current line after <range>move command
Note: The behavior associated with this assertion is expected
to change in a future revision of POSIX.2.
expected current line 2, was line 3
Command failed: 'checkline ex_data_1 2'
expected current line 3, was line 4
Command failed: 'checkline ex_data_2 3'
Assertion Result: FAIL
Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
Anticipating acceptance of the completely rewritten ex specification
in POSIX 2003.2b/D11 and the eventual alignment of the tests with it
a temporary interpretation is recommended.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Temporary Interpretation (TIN) Review Conclusion
A Temporary Interpretation is granted.
Problem Reporting System Options:
- View Report 0756
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority