Report 0741 Actions
Problem Report Number 0741 Submitter's Classification Specification problem State Resolved Resolution Temporary Interpretation (TIN) Problem Resolution ID TIN.X.0032 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1995-10-30 08:00 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.4 Test Identification POSIX.upe/vi 275 Specification Commands and Utilities Issue 4 Version 2 Location in Spec See Problem Text Problem Summary TIN4C.00029 The test may fail on implementations that adhere to POSIX.2b and do not copy the previously inserted text into the numeric named buffers when an undo command is executed. Problem Text
The test may fail on implementations that adhere to POSIX.2b and do
not copy the previously inserted text into the numeric named buffers
when an undo command is executed.
The test verifies the POSIX 1003.2 assertion that after inserting a
few lines the undo command will remove those lines and place them in
a numeric buffer.
Historically, the undo command would remove the lines without placing
them in any buffer. POSIX 1003.2b/D11 has reinstated this as the
mandated behavior.
Our implementation conforms to the draft POSIX.2b standard which mandates
this historical practice. Since this area of the specification is subject
to change, we request a temporary interpretation allowing historical practice.Test Output
400|13 275 1 01:49:26|IC Start
200|13 1 01:49:26|TP Start
520|13 1 446693380 1 1|Assertion #275 (C): u puts text in numbered buffer
520|13 1 446693380 1 1|Note: The behavior associated with this assertion is expected
520|13 1 446693380 1 2|to change in a future revision of POSIX.2.
520|13 1 446693380 1 3|Standard output isn't the same as file 'vi_exp_1'
520|13 1 446693380 1 4|diff of "out.stdout" and "vi_exp_1":
520|13 1 446693380 1 5|*** out.stdout Fri Aug 18 01:49:39 1995
520|13 1 446693380 1 6|--- vi_exp_1 Fri Aug 18 01:49:29 1995
520|13 1 446693380 1 7|***************
520|13 1 446693380 1 8|*** 2,4 ****
520|13 1 446693380 1 9|--- 2,6 ----
520|13 1 446693380 1 10| second
520|13 1 446693380 1 11| penultimate
520|13 1 446693380 1 12| last
520|13 1 446693380 1 13|+ hello
520|13 1 446693380 1 14|+ world
220|13 1 1 01:49:50|FAIL
410|13 275 1 01:49:50|IC EndReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
Anticipating acceptance of the completely rewritten vi specification
in POSIX 2003.2b/D11 and the eventual alignment of the tests with it
a temporary interpretation is recommended.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Temporary Interpretation (TIN) Review Conclusion
A Temporary Interpretation is granted.