Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0635 Details Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0635.
Report 0635 Actions
Problem Report Number 0635 Submitter's Classification Specification problem State Resolved Resolution Rejected (REJ) Problem Resolution ID REJ.X.0239 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published null Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.4 Test Identification POSIX.upe/ex 352 Problem Summary PG4C.00037 The test does not properly test output redirection when using the option, warn. Problem Text
The test assertions listed test an area of POSIX.2 which does not reflect
historical practice. The draft POSIX.2b standard more closely documents
the behaviour of historical implementation of Ex and Vi.
Historically, when warn edit option is set, any warning message was written
to standard output. The correct behaviour is described in POSIX.2b draft.11
section 5.10.6.1 page 128 lines 302-303, section 5.10.78.28 page 174 lines
2010-2012, and section E.5.10.6.2 page 287 lines 907-910.
Our implementation conforms to the draft POSIX.2b standard which mandates
this historical practice. Since this area of the specification is subject
to change, we request a temporary interpretation allowing historical practice.Test Output
400|16 352 1 09:30:01|IC Start
200|16 1 09:30:01|TP Start
520|16 1 98893851 1 1|Assertion #352 (C): yank<buff> yanks lines from file into named buffer
520|16 1 98893851 1 1|Note: The behavior associated with this assertion is expected
520|16 1 98893851 1 2|to change in a future revision of POSIX.2.
520|16 1 98893851 1 3|diff of "ex_data_1" and "ex_exp_1":
520|16 1 98893851 1 4|6d5
520|16 1 98893851 1 5|< ghi
520|16 1 98893851 1 6|Command failed: 'jrnl_file_diff ex_data_1 ex_exp_1'
220|16 1 1 09:30:17|FAIL
410|16 352 1 09:30:18|IC EndReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
We recommend this request be refused.
The interpretation request journal output does not match the reasons
provided in the comment section. Test purpose 352 appears to be
failing properly.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Rejected (REJ) Review Conclusion
This request is refused.
Problem Reporting System Options:
- View Report 0635
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority