HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0632 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0632.


Report 0632 Actions


    Problem Report Number 0632
    Submitter's Classification Specification problem
    State Resolved
    Resolution Rejected (REJ)
    Problem Resolution ID REJ.X.0236
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published null
    Product Standard Commands and Utilities V2 (UNIX 95)
    Certification Program The Open Brand certification program
    Test Suite VSC version 4.1.4
    Test Identification POSIX.upe/ex 255
    Problem Summary PG4C.00040 This was refused because it is a duplicate. Use TSD4C.00004 instead.
    Problem Text
    The test assertions listed test an area of POSIX.2 which the POSIX.2
    interpretation committe has determined to be in error (see IEEE
    interpretations PASC 1003.2-92 #78, question #32).

    Historically, :rewind set the current line as described by :edit. The correct
    behaviour is described in POSIX.2b draft.11 section 5.10.7.5.26 page 157 line
    1398

    Our implementation conforms to the draft POSIX.2b standard which mandates
    this historical practice. Since this area of the specification is subject
    to change, we request a temporary interpretation allowing historical practice.

    Test Output
    200|13 1 08:52:01|TP Start
    520|13 1 84738078 1 1|Assertion #255 (C): rewind command fails if modified buffer not saved
    520|13 1 84738078 1 1|Note: The behavior associated with this assertion is expected
    520|13 1 84738078 1 2|to change in a future revision of POSIX.2.
    220|13 1 0 08:52:23|PASS
    410|13 255 1 08:52:24|IC End

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    We recommend this request be refused.

    The test results show the test is PASSing but the submitter claims
    the IUT does not perform as the test expects. These two things are
    at odds with each other.

    In any event there is already a ruling, TSD4C.00004, regarding
    the issue being raised.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Rejected (REJ)
    Review Conclusion
    This request is refused.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority