HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0617 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0617.


Report 0617 Actions


    Problem Report Number 0617
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Rejected (REJ)
    Problem Resolution ID REJ.X.0221
    Raised 1970-01-01 08:00
    Updated 2003-03-13 08:00
    Published null
    Product Standard Commands and Utilities V2 (UNIX 95)
    Certification Program The Open Brand certification program
    Test Suite VSC version 4.1.5
    Test Identification POSIX.upe/more 10
    Problem Summary PG4C.00055 The test prints the error"I/O resynchronization failed" then FAILs.
    Problem Text
    Many tests for the more utility are getting this "I/O resynchronization
    failed" message and we cannot determine where the problem lies. We have
    tried increasing timer values in Src/ImplSpec/libexec.exp but the
    problem persists.

    We need assistance to debug this problem.
    Test Output
    520|31 1 27852823 1 1|Assertion #10 (C): GA20: space allowed between options an
    520|31 1 27852823 1 2| <LC> d arguments
    520|31 1 27852823 1 11|Expected exit code = 0; Received 2
    520|31 1 27852823 1 12|Standard error isn't empty
    520|31 1 27852823 1 13|Contents of out.stderr:
    520|31 1 27852823 1 14|termin: I/O resynchronization failed
    520|31 1 27852823 1 15|Expected exit code = 0; Received 2
    520|31 1 27852823 1 16|Standard error isn't empty
    520|31 1 27852823 1 17|Contents of out.stderr:
    520|31 1 27852823 1 18|termin: I/O resynchronization failed
    220|31 1 1 13:36:56|FAIL

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    We recommend this request be refused.

    We believe the test is correct.

    The test is executes lines of the following form:

    feed '1G 30G f' | termin -s $cmd -n 10 more_in_1

    After the '1G 30G f' sequence is sent to the more process,
    the feed function sends a command sequence to mark the location
    using the v command. When the v command completes, the standard
    states in the description of "Invoke Editor" in the more utility
    Extended Description section,

    When the editor exits, more will resume on the
    current file by rewriting the screen with the
    current line as the current position.

    The "I/O resynchronization failed" message occurs because the unexpected
    prompt, "[Hit return to continue]" occurs when the editor exits. The
    test eventually times out which leads to the error shown above.

    Please note that the interpretation process is not well suited for obtaining
    help to debug problems. Please use vsc_support.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Rejected (REJ)
    Review Conclusion
    This request is refused.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority