Problem Report Number 0617 Submitter's Classification Test Suite problem State Resolved Resolution Rejected (REJ) Problem Resolution ID REJ.X.0221 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published null Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.5 Test Identification POSIX.upe/more 10 Problem Summary PG4C.00055 The test prints the error"I/O resynchronization failed" then FAILs. Problem Text
Many tests for the more utility are getting this "I/O resynchronization
failed" message and we cannot determine where the problem lies. We have
tried increasing timer values in Src/ImplSpec/libexec.exp but the
problem persists.
We need assistance to debug this problem.Test Output
520|31 1 27852823 1 1|Assertion #10 (C): GA20: space allowed between options an
520|31 1 27852823 1 2| <LC> d arguments
520|31 1 27852823 1 11|Expected exit code = 0; Received 2
520|31 1 27852823 1 12|Standard error isn't empty
520|31 1 27852823 1 13|Contents of out.stderr:
520|31 1 27852823 1 14|termin: I/O resynchronization failed
520|31 1 27852823 1 15|Expected exit code = 0; Received 2
520|31 1 27852823 1 16|Standard error isn't empty
520|31 1 27852823 1 17|Contents of out.stderr:
520|31 1 27852823 1 18|termin: I/O resynchronization failed
220|31 1 1 13:36:56|FAILReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
We recommend this request be refused.
We believe the test is correct.
The test is executes lines of the following form:
feed '1G 30G f' | termin -s $cmd -n 10 more_in_1
After the '1G 30G f' sequence is sent to the more process,
the feed function sends a command sequence to mark the location
using the v command. When the v command completes, the standard
states in the description of "Invoke Editor" in the more utility
Extended Description section,
When the editor exits, more will resume on the
current file by rewriting the screen with the
current line as the current position.
The "I/O resynchronization failed" message occurs because the unexpected
prompt, "[Hit return to continue]" occurs when the editor exits. The
test eventually times out which leads to the error shown above.
Please note that the interpretation process is not well suited for obtaining
help to debug problems. Please use vsc_support.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Rejected (REJ) Review Conclusion
This request is refused.