Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0543 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0543.
Report 0543 Actions
Problem Report Number 0543 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0034 Raised 1970-01-01 08:00 Updated 2003-03-13 08:00 Published 1996-01-02 08:00 Expiry Date 1997-01-02 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite VSC version 4.1.4 Test Identification POSIX.annexC/fort77 8,9,10 Problem Summary MSF4C.00004 A MSF is requested because _POSIX2_FORT_DEV is defined even though the X/Open fort77 option is not supported. Problem Text
A MSF is requested because _POSIX2_FORT_DEV is defined
even though the X/Open fort77 option is not supported.
For this release, we intend to brand by claiming not to support the fort77
utility. However due to this system fault, we can't turn off the
_POSIX2_FORT_DEV. Consequently, fort77 cases 8, 9, 10 failed.
Getconf returns hard coded values instead of values of variables
returned from sysconf, the current state of the compiler is not being
reported correctly.
This problem only affects users who depend on development environment
variable _POSIX2_FORT_DEV, and as such does not affect portable applications.Test Output
520|499 1 1689 1 1|Assertion #8 (C): GA29
520|499 1 1689 1 1|Expected exit code = 0; Received 1
520|499 1 1689 1 2|Standard error isn't empty
520|499 1 1689 1 3|Contents of out.stderr:
520|499 1 1689 1 4|fort77: Cannot read file 0
520|499 1 1689 1 5|fort77: Errors detected
520|499 1 1689 1 6|Expected exit code = 0; Received 1
520|499 1 1689 1 7|Standard error isn't empty
520|499 1 1689 1 8|Contents of out.stderr:
520|499 1 1689 1 9|fort77: Cannot read file 0
520|499 1 1689 1 10|fort77: Errors detected
520|499 1 1689 1 11|Expected exit code = 0; Received 1
520|499 1 1689 1 12|Standard error isn't empty
520|499 1 1689 1 13|Contents of out.stderr:
520|499 1 1689 1 14|fort77: Cannot read file 0
520|499 1 1689 1 15|fort77: Errors detected
520|499 1 1689 1 16|Expected exit code = 0; Received 1
520|499 1 1689 1 17|Standard error isn't empty
520|499 1 1689 1 18|Contents of out.stderr:
520|499 1 1689 1 19|fort77: Cannot read file 0
520|499 1 1689 1 20|fort77: Errors detected
220|499 1 1 11:36:15|FAIL
410|499 8 1 11:36:15|IC End
400|499 9 1 11:36:15|IC Start
200|499 1 11:36:15|TP Start
520|499 1 1689 1 1|Assertion #9 (C): GA20
520|499 1 1689 1 1|Expected exit code = 0; Received 1
520|499 1 1689 1 2|Standard error isn't empty
520|499 1 1689 1 3|Contents of out.stderr:
520|499 1 1689 1 4|fort77: Cannot read file 1
520|499 1 1689 1 5|fort77: Errors detected, no link
220|499 1 1 11:36:17|FAIL
410|499 9 1 11:36:17|IC End
400|499 10 1 11:36:17|IC Start
200|499 1 11:36:17|TP Start
520|499 1 1689 1 1|Assertion #10 (C): GA27
520|499 1 1689 1 1|Expected exit code != 0; Received 0
220|499 1 1 11:36:20|FAIL
410|499 10 1 11:36:20|IC EndReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
A temporary waiver for a minor system fault is recommended.
We believe this issue is unlikely to cause anyone inconvienence.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion
A Temporary Waiver is granted.
Problem Reporting System Options:
- View Report 0543
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority