Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0480 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0480.
Report 0480 Actions
Problem Report Number 0480 Submitter's Classification Test Suite problem State Resolved Resolution Rejected (REJ) Problem Resolution ID REJ.X.0099 Raised 1995-03-23 08:00 Updated 2003-03-13 08:00 Published null Product Standard Internationalised System Calls and Libraries (XPG4) Certification Program The Open Brand certification program Test Suite VSX4 version 4.3.4 Test Identification POSIX.os/devclass/cfsetospee 2 Linked Problem Reports TSD4.073, (in, old, system) Problem Summary PG4R.100 This is a known test suite deficiency. Problem Text
This is a known test suite deficiency.Test Output
************************************************************************
/tset/POSIX.os/devclass/cfsetospee/T.cfsetospee 2 Failed
Test Description:
If general terminal interface supported:
For each of the baud rates B50, B75, B110, B134, B150, B200, B300,
B600, B1200, B1800, B2400, B4800, B9600, B19200 and B38400 a
successful call to cfsetospeed() followed by a call to tcsetattr()
shall set the output baud rate to the corresponding speed. At
least one of these baud rates shall be supported.
Posix Ref: Component CFSETOSPEED Assertion 7.1.2.7.2-05(C)
Test Strategy:
SET IXON in loop back termios structure SET IXOFF in terminal termios
structure
For each of the specified baud rates:
SET input/output baud rate in terminal structure using
cfsetispeed()/cfsetospeed()
SET terminal information using tcsetattr()
OBTAIN terminal information using tcgetattr()
If input/output baud rate is not set to specified baud rate, baud rate
is not supported
SET input/output baud rate in loop back terminal structure using
cfsetispeed()/cfsetospeed()
SET terminal information using tcsetattr()
OBTAIN terminal information using tcgetattr()
If input/output baud rate is not set to specified baud rate, baud rate
is not supported
If baud rate is supported, CREATE [child process|process pair]
Child: SLEEP using sleep() to allow terminal file to initialise
SET time out.
WRITE data to loop back file using write()
VERIFY that data was written within twice the expected write time
Parent: READ from terminal file using read()
VERIFY that all written data can be read
VERIFY that at least one of the specified baud rates is supported
Test Information:
read error. B9600 test failed
read error. B19200 test failed
read error. B38400 test failed
************************************************************************Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
This test suite failure is covered by interpretation TSD4.162.
It is recommended that this request is refused.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Rejected (REJ) Review Conclusion
This request is refused.