HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0431 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0431.


Report 0431 Actions


    Problem Report Number 0431
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Rejected (REJ)
    Problem Resolution ID REJ.X.0050
    Raised 1993-12-10 08:00
    Updated 2003-03-13 08:00
    Published null
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.3.2
    Test Identification ANSI.os/streamio/fseek 12
    Linked Problem Reports TIN4.004, (in, old, system)
    Problem Summary PG4R.050 The X/Open Verification Suite Release Notes 4.3.2 (page 6) states that there is temporary X/Open interpretation for fseek() on pipes and FIFOs (TIN4.004). This indicates that the test is incorrect. Th...
    Problem Text
    The X/Open Verification Suite Release Notes 4.3.2 (page 6) states that
    there is temporary X/Open interpretation for fseek() on pipes and
    FIFOs (TIN4.004). This indicates that the test is incorrect. The test expects
    a subsequent getc() on the stream to be unaffected by the fseek() call.
    Test Output
    /tset/ANSI.os/streamio/fseek/T.fseek 12 Failed
    getc() after fseek() on FIFO did not return next byte written to FIFO
    getc() after fseek() on pipe did not return next byte written to pipe

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    I think that the submitter is confused about the process of referencing
    standing interpretations. This request came through a couple of days
    ago and the response was to refer to TIN4.004. This request does exactly
    that, but the reference should be made on the test report submitted with
    the branding application not through another interpretation request.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Rejected (REJ)
    Review Conclusion
    This request is refused.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority