Problem Report Number 0377 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0018 Raised 1997-02-11 08:00 Updated 2003-03-13 08:00 Published 1997-02-17 08:00 Expiry Date 1998-02-16 Product Standard Internationalised System Calls and Libraries (XPG4) Certification Program The Open Brand certification program Test Suite VSX4 version 4.3.5 Test Identification POSIX.os/devclass/tcsetattr 2 Problem Summary MSF4.018 The test failed intermittently, need more time to investigate the system deficiency. Problem Text
The test failed intermittently, need more time to investigate
the system deficiency.Test Output
Test Description:
If general terminal interface supported:
When tcsetattr(fildes, TCSADRAIN, termios_p) is called from a
foreground process, it shall set the parameters associated with the
terminal described by fildes from the termios structure referenced
by termios_p, and shall return zero. The call to tcsetattr() shall
wait for data in the terminal's output queue to be drained.
Posix Ref: Component TCSETATTR Assertion 7.2.1.2-06(C)
Test Strategy:
OPEN and initialise terminal file and loop back file
SET time out for WAITTIME
WRITE data to loop back file using write()
WRITE data to terminal file using write()
OBTAIN terminal information using tcgetattr(tty_fildes, tty_termios_p)
SET terminal information using tcsetattr(tty_fildes, TCSADRAIN,
tty_termios_p)
VERIFY that tcsetattr() returned zero.
FLUSH output terminal file data using tcflush()
(This will discard any terminal output not yet transmitted)
SLEEP to allow data to become available for reading
SET time out for WAITTIME
READ from loop back file using read()
VERIFY that no terminal output was discarded
10|0 /tset/POSIX.os/devclass/tcsetattr/T.tcsetattr 18:23:48|TC Start, scenario
ref 0-1, ICs {2}
200|0 2 18:23:55|TP Start
520|0 2 630 1 2|tcsetattr(TCSADRAIN) did not drain output
220|0 2 1 18:24:56|FAIL
410|0 2 1 18:24:56|IC EndReview Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
It is accepted that this situation is unlikely to affect
portable applications.
This is agreed to be a minor system fault and a Temporary Waiver is
recommended.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion
A Temporary Waiver is granted.