Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0360 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0360.
Report 0360 Actions
Problem Report Number 0360 Submitter's Classification Minor System Fault State Resolved Resolution Minor System Fault (MSF) Problem Resolution ID MSF.X.0001 Raised 1992-09-19 08:00 Updated 2003-03-13 08:00 Published 1992-09-29 08:00 Expiry Date 1993-09-29 Product Standard Internationalised System Calls and Libraries (XPG4) Certification Program The Open Brand certification program Test Suite VSX4 version 4.2.3 Test Identification XOPEN.os/genuts/encrypt 2 Problem Summary MSF4.001 This problem will be investigated and fixed in the next release. Problem Text
This problem will be investigated and fixed in the next release.Test Output
******************************************************************
/tset/XOPEN.os/genuts/encrypt 2 Failed
encrypt() with edflag 1 did not decrypt the string given as its
first argument.
******************************************************************Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
There are few applications which make use of encryption and decryption
interfaces, and as such this problem would not affect many applications.
A temporary waiver would not be inappropriate in these circumstances.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Minor System Fault (MSF) Review Conclusion
A Temporary Waiver is granted.
Problem Reporting System Options:
- View Report 0360
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual