HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0333 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0333.


Report 0333 Actions


    Problem Report Number 0333
    Submitter's Classification Specification problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0049
    Raised 1995-09-27 08:00
    Updated 2003-03-13 08:00
    Published 1995-10-09 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.3.5
    Test Identification POSIX.hdr/misc/unistd_1 6
    Specification System Interfaces and Headers Issue 4
    Location in Spec See Problem Text
    Problem Summary PIN4.049 The returned value, 199506, correctly reflects our system's
    compliance with IEEE Std.1003.1c-1995, and indicates that the standard
    was accepted by the IEEE in June, 1995. We request that this interpr...
    Problem Text The returned value, 199506, correctly reflects our system's compliance
    with IEEE Std.1003.1c-1995, and indicates that the standard was accepted
    by the IEEE in June, 1995.

    We request that this interpretation also allow subsequent version
    numbers that also identify the compliance level of the product and the
    acceptance date of the standards.
    Test Output Test Results:

    /tset/POSIX.hdr/misc/unistd_1/T.unistd_1 6 Failed

    Test Information:

    Feature test macros: -D_XOPEN_SOURCE
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
    -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
    -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199506

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response It is recommended that a Permanent Interpretation is granted on the basis
    that conformance to a later revision of the IEEE standard does not negate
    conformance to XPG 4.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion A Permanent Interpretation is granted.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority