HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0312 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0312.


Report 0312 Actions


    Problem Report Number 0312
    Submitter's Classification Specification problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0028
    Raised 1994-05-06 08:00
    Updated 2003-03-13 08:00
    Published 1994-05-31 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.3.4
    Test Identification POSIX.hdr/misc/unistd_1 6
    Specification System Interfaces and Headers Issue 4
    Location in Spec See Problem Text
    Problem Summary PIN4.028 "X/Open System Interfaces and Headers, Issue 4" has the following description of the _POSIX_VERSION in <unistd.h>. _POSIX_VERSION Integer value indicating version of the ISO POSIX-1 standard (C langua...
    Problem Text
    "X/Open System Interfaces and Headers, Issue 4" has the following
    description of the _POSIX_VERSION in <unistd.h>.

    _POSIX_VERSION Integer value indicating version of the ISO POSIX-1
    standard (C language binding).


    Our operating system claims conformance to IEEE Std 1003.1b-1993
    which requires that _POSIX_VERSION be set to 199309L.

    XPG4 should not preclude adherence to the current IEEE/ANSI/ISO
    standard by requiring that _POSIX_VERSION be set to 199009L.

    Waivers were granted for similar problems with the VSX3 suite (PG3.700,
    PG3.625, PG3.469, ...), but were not cited in the appropriate field
    since they are referring to a different version of the VSX suite.

    Test Output

    ************************************************************************
    /tset/POSIX.hdr/misc/unistd_1/T.unistd_1 6 Failed

    Test Information:
    Feature test macros: -D_XOPEN_SOURCE
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX_VERSION has an invalid value
    Should have the value: 199009
    Actually had the value: 199309
    ************************************************************************

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    Since IEEE Std 1003.1b-1993 is a set of additions to the IEEE Std 1003.1-1990
    and does not make changes to the syntax or semantics of the calls in the
    XSH4 specifications, it seems reasonable to recommend that a permanent waiver
    be granted for this difference. There is a precedent for this in the
    change from IEEE Std 1003.1-1988 to IEEE Std 1003.1-1990.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion
    A Permanent Interpretation is granted.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority