Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0303 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0303.
Report 0303 Actions
Problem Report Number 0303 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0019 Raised 1994-01-19 08:00 Updated 2003-03-13 08:00 Published 1994-02-22 08:00 Product Standard Commands and Utilities V2 (UNIX 95) Certification Program The Open Brand certification program Test Suite Unknown version N/A Test Identification N/A Specification Commands and Utilities Issue 4 Version 2 Location in Spec See Problem Text Problem Summary PIN4.019 In XCU4, commands uucp, uustat and uux are not listed in the table of "Possibly Unsupportable Features" that can be found in chapter 1.3.4; but, on the contrary, the individual command definitions are... Problem Text
In XCU4, commands uucp, uustat and uux are not listed in the table of
"Possibly Unsupportable Features" that can be found in chapter 1.3.4;
but, on the contrary, the individual command definitions are marked
as "Possibly Unsupportable Features".
The description of a "possibly unsupportable feature" states that:
It need not be possible to implement the required functionality
(as defined) on all XSI-conformant systems and the functionality
need not be present.
I assume this phrase means that this phrase means that the requirements
of an XSI-conformant system can be met by providing an instance of the
command which always returns an error irrespective of the options and
arguments present with the command.Test Output Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
It seems reasonable that when an implementation is unable to
provide an possibly unsupportable feature that it provides a simple stub
for the utility that always indicates that an error has occured. This
ensures that the application does not fail because the utility has not
been found and indicates to the application that the utility was unable
to perform the actions requested.
A permanent interpretation is recommended for an implementation which
behaves as described.No Discussion comments in this Review.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion
A permanent interpretation is granted.