Home About Us A-Z Index Search * Contact Us Register Login Press ShopThe Open Brand -- Problem Reporting and Interpretations System |
Problem Report 0289 Details
Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges
This page provides all information on Problem Report 0289.
Report 0289 Actions
Problem Report Number 0289 Submitter's Classification Specification problem State Resolved Resolution Permanent Interpretation (PIN) Problem Resolution ID PIN.X.0005 Raised 1992-09-30 08:00 Updated 2003-03-13 08:00 Published 1992-10-06 08:00 Product Standard Internationalised System Calls and Libraries (XPG4) Certification Program The Open Brand certification program Test Suite VSX4 version 4.2.3 Test Identification POSIX.hdr/misc/unistd 25 Specification System Interfaces and Headers Issue 4 Location in Spec See Problem Text Problem Summary PIN4.005 This is a known problem documented in the VSX4.2.3 release notes. This is similar to our earlier waiver, except that this system configuration does not support the XCU4 commands. There is a pending ru... Problem Text
This is a known problem documented in the VSX4.2.3 release notes.
This is similar to our earlier waiver, except that this system
configuration does not support the XCU4 commands.
There is a pending ruling from XoTGbase (VWG/029/160992) that would allow
a system configured without the XCU4 commands to return -1 for the
_POSIX2_VERSION.Test Output
************************************************************************
/tset/POSIX.hdr/misc/unistd_X/T.unistd_X 25 Failed
Test Description:
The header file contains a definition for the symbolic constant
_POSIX2_VERSION which has the required integer value.
Not tested in XPG3 mode.
Test Strategy:
COMPILE program including <unistd.h>.
VERIFY symbolic constant exists using #ifndef.
VERIFY value of constant is as expected.
VERIFY there were no compiler errors.
Test Information:
Feature test macros: -D_XOPEN_SOURCE
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=1
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=2
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=1
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=2
Compiler or run-time messages or results:
_POSIX2_VERSION has incorrect value
Expected value: 999999
Observed value: -1
************************************************************************Review Information
Review Type TSMA Review Start Date null Completed null Status Complete Review Recommendation No Resolution Given Review Response
The K/RT interpretation VWG/029/160992 states that _POSIX2_VERSION can be
set to -1 to indicate that the system does not support the XCU4 command
behaviour. This behaviour will be accepted in the next release of VSX.
Review Type SA Review Start Date null Completed null Status Complete Review Resolution Permanent Interpretation (PIN) Review Conclusion
A Permanent Interpretation is granted.
Problem Reporting System Options:
- View Report 0289
- List All PRs
- Search Reports
- Email the System Administrator
- View the The Open Brand Interpretations Database User Manual
Contact the Certification Authority