Report 0289 Actions


    Problem Report Number 0289
    Submitter's Classification Specification problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0005
    Raised 1992-09-30 08:00
    Updated 2003-03-13 08:00
    Published 1992-10-06 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.3
    Test Identification POSIX.hdr/misc/unistd 25
    Specification System Interfaces and Headers Issue 4
    Location in Spec See Problem Text
    Problem Summary PIN4.005 This is a known problem documented in the VSX4.2.3 release notes. This is similar to our earlier waiver, except that this system configuration does not support the XCU4 commands. There is a pending ru...
    Problem Text
    This is a known problem documented in the VSX4.2.3 release notes.
    This is similar to our earlier waiver, except that this system
    configuration does not support the XCU4 commands.
    There is a pending ruling from XoTGbase (VWG/029/160992) that would allow
    a system configured without the XCU4 commands to return -1 for the
    _POSIX2_VERSION.
    Test Output
    ************************************************************************
    /tset/POSIX.hdr/misc/unistd_X/T.unistd_X 25 Failed

    Test Description:
    The header file contains a definition for the symbolic constant
    _POSIX2_VERSION which has the required integer value.
    Not tested in XPG3 mode.

    Test Strategy:
    COMPILE program including <unistd.h>.
    VERIFY symbolic constant exists using #ifndef.
    VERIFY value of constant is as expected.
    VERIFY there were no compiler errors.

    Test Information:
    Feature test macros: -D_XOPEN_SOURCE
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=1
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    Feature test macros: -D_XOPEN_SOURCE -D_POSIX_SOURCE -D_POSIX_C_SOURCE=2
    Compiler or run-time messages or results:
    _POSIX2_VERSION has incorrect value
    Expected value: 999999
    Observed value: -1
    ************************************************************************

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    The K/RT interpretation VWG/029/160992 states that _POSIX2_VERSION can be
    set to -1 to indicate that the system does not support the XCU4 command
    behaviour. This behaviour will be accepted in the next release of VSX.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion
    A Permanent Interpretation is granted.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority