Report 0286 Actions


    Problem Report Number 0286
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Permanent Interpretation (PIN)
    Problem Resolution ID PIN.X.0002
    Raised 1992-09-19 08:00
    Updated 2003-03-13 08:00
    Published 1992-09-29 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.3
    Test Identification XPG4.os/wstring/wcsxfrm 5
    Specification System Interfaces and Headers Issue 4
    Location in Spec See Problem Text
    Problem Summary PIN4.002 This test fails since _XOPEN_ENH_I18N is set to -1 and wcsftime returns NOERROR when ENOSYS was expected. A recent 'interpretation' decided it was permitted to support some but not necessarily all o...
    Problem Text
    This test fails since _XOPEN_ENH_I18N is set to -1 and wcsftime returns
    NOERROR when ENOSYS was expected.
    A recent 'interpretation' decided it was permitted to support some but
    not necessarily all of the 'enhanced' facilities.
    Test Output
    wcsxfrm() did not return expected value
    Expected return value (size_t)-1
    Actual return value 0
    wcscoll() did not sett errno correctly
    Expected 48 (ENOSYS)
    Actual 0 (NO ERROR)

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    This is accepted as an interpretation from the K/RT group and a permanent
    waiver is recommended.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Permanent Interpretation (PIN)
    Review Conclusion
    A Permanent Interpretation is granted.